MEWOI9300B Clamp on Leakage Current Monitoring Recorder
Ⅰ. INTRODUCTION
Click to download: MEWOI9300B User Manual
MEWOI9300B Series Three-Channel Current/Leakage Monitoring Recorder is well designed and manufactured for online measurement, monitoring and recording of Three-Channel AC leakage / current at the same time. It is composed of a tester, monitoring software, current clamp and communication cable, etc. This instrument has been widely applied the 380/220 Power system. It can provide a safety and convenience measurement with accurate results. The instrument has a large LCD display with blue background and a large storage space. 3900 sets of data can be stored in the instrument. Three- channel current value can be display on the screen. In addition, the instrument can automatically store data at a interval, which is adjustable from 1 to 99 min. Monitoring software provides online and real-time monitoring and historical data inquiry. With the software developed by our technical department, the users can read, inquire, store, generate and print a fitting curve and report. The current clamp is made of a special alloy, adopts the latest CT technique and magnetic shielding technique and is not almost interfered by external magnetic field. This ensures high accuracy, high stability and high reliability of the values which are measured continuously. |
Ⅱ. Technical Specification
Functions | online monitoring and recording 1 ~ 3 channel AC leakage current and current, used for circuit insulation fault troubleshooting, monitoring intermittent leakage fault, check the happen time of insulation fault and maintenance lines, etc. |
Power Supply | DC 3.7V rechargeable lithium battery(full charge about 4.2V) |
Test Mode | Clamp CT, true RMS |
Display Mode | LCD:128dots×64dots |
Current Clamp | 1-3PCS(Optional) |
Instrument Dimension | Host:78mm×165mm ×42mm Current clamp 040A: 125mm×70mm×37mm |
Weight | Host: 330g Current clamp 040A: 190g |
LCD Dimension | Display field:44mm×27mm |
Current Clamp Model | 040A |
Current Clamp Lead Cable | 2 core shield wire, length 2M |
Sampling Rate | 2 times/second |
Data storage | 200,000 groups (Power down or replace battery will not lose the data) |
Record Period | Set the record interval time within 1 second ~ 99 minutes, 0 seconds is not automatically stored. |
Record Time | Interval time 1 seconds, can continues recording 48 hours |
Interval time 10 seconds, can continues recording 120 hours | |
Interval time 1 minute, can continues recording 168 hours | |
Download Speed | 60KB/ Min |
Line Voltage | Below AC600V circuit test |
Overflow Display | Exceed measure range overflow function: "OL" symbol display |
Battery Voltage | Use 3.7V rechargeable lithium battery, power energy display with 3-grid, when the power energy is 0-grid indicate battery voltage is low, please charge in time |
Rated Power | In power save mode about 6mA, Max about 35mA |
Communication Interface | USB |
Record Time | In power save mode continues working 7days |
Working Temperature | Working:-20℃~50℃;below 80%rh |
Temperature Error | Below -10℃ or above 40℃ error influence 1% |
Stored Temperature | Storage:-10℃~60℃;below 70%rh |
Insulation Resistance | 100MΩ or larger, 1000V |
Suitable Safety Standard | IEC1010-1, IEC1010-2-032, Pollution Class 2, CATⅢ(600V),IEC61326(EMC standard) |
SELECTION GUIDE 1
Clamp on Leakage Current Monitoring Recorder
Click "Blue" marked MODEL NO.to view the spec
Model | Range | Resolution | Clamp Size | Data Storge | Channels | Connection Type |
MEWOI9000 | 0.0A-500A | 0.1A | 35mm×40mm | 4200Sets | Single | Wired |
MEWOI9000C | 0.00mA-20A | 0.01mA | 25mm×30mm | 4200Sets | Single | Wired |
MEWOI9300B | 0.0A-500A | 0.1A | 35mm×40mm | 200000Sets | Three-Channels | Wired |
MEWOI9300 | 0.00mA-20A | 0.01mA | 25mm×30mm | 20000Sets | Three-Channels | Wired |
MEWOI9500-130T | 0.000mA-60.00A | 1uA | 25mm×30mm | 3000Sets | 1-8 Channels | Wireless |
MEWOI9500-140T | 0.00mA ~ 300.0A | 0.01mA | 35mm×40mm | 3000Sets | 1-8 Channels | Wireless |
MEWOI9500-168T | 0.00mA ~ 1200A | 0.01mA | φ68mm | 3000Sets | 1-8 Channels | Wireless |
Technical Specification
Functions | Measuring AC leakage current and AC current, monitoring current in real-time manner, locating insulation faults and repairing electrical lines. |
Power source | DC6V, alkaline battery LR03 1.5V×4 |
Testing Method | Clamp CT, TRMS |
Range | 0.00mA-20A |
Resolution | 0.01mA |
Accuracy | ±2%±5dgt |
Clamp size | 25mm×30mm |
Instrument Dimension | Tester(L×W×H): 75mm ×170mm ×30mm, Current clamp(L×W×H): 122mm ×70mm ×33mm |
Mass | Tester: 410g (battery included),Current clamp: 170g |
LCD Dimension | Display field: 44mm×27mm |
Shield Type | Type B: Double shielding |
Sampling Rate | 2 samples/s |
Data storage | 3900 sets (data loss does not occur after power failure or replacing the battery) |
Time Setting | Recording internal adjustable from 1 to 60 min, If set to 0 min, the auto-store function is turned off |
Recording Time | Continuously operate for about 10 days at the power-saving mode |
Line Voltage | Line with a voltage up to AC600V |
Overflow Display | The “OL” symbol is displayed when a measured value is beyond the measurement range |
Battery. Voltage | A Low-Battery symbol is displayed and the user should replace the battery with a new one when the battery voltage drops to 4.6V to 4.8V. In this case, the measured values are still accurate. |
Rated Power | about 5mA at the power-saving mode, maximum current consumption: 20mA |
Lead Length | 2 m |
Temperature and Humidity | Working: -20℃~50℃;below 80%rh |
Storage: -20℃~50℃;below 70%rh | |
Insulation Resistance | Higher than 100MΩ, 1000V |
Safety Codes | IEC1010-1, IEC1010-2-032, Pollution Class 2, CAT Ⅲ(600V), IEC61326(EMC standard) |
Accessories | Tester: 1 PCS, Current clamp: 3PCS, Instrument bag: 1 PCS, RS232 Com-cable:1 PCS; Software Disk: 1 PCS |
Tester: 1 PCS, Current clamp: 3PCS, Instrument bag: 1 PCS, RS232 Com-cable:1 PCS; Software Disk: 1 PCS