MEWOI9300 Three-Channel Clamp on Leakage Current Monitoring Recorder

OEM/ODM Testing Instruments Manufacturer

  • Main Features:: 1,Measuring AC leakage current and AC current 2,Range:0mA-500A,3,Resolution:0.1A,4,Clamp size:35mm×40mm,5,Data storage:3900Set
  • Model No.:: MEWOI9300
  • Name:: MEWOI9300 Three-Channel Clamp on Leakage Current Monitoring Recorder

MEWOI9300  Clamp on Leakage Current Monitoring Recorder

Ⅰ. INTRODUCTION

Click to download: MEWOI9300 User Manual

Click to download: MEWOI9300 Color Page

MEWOI9300 Three-Channel Leakage Current Monitoring Recorderis designed and manufactured for on-site simultaneous monitoring and recording 1-3 channel AC current or leakage current, it is composed of recorder host, current clamps, charger, monitoring software and communication cable, etc. Widely used in 380/220v power system, provide safe, accurate and convenient power instrument for power inspectors.

Host adopts LCD display, three channels with the same screen display, clear at a glance, there are Chinese and English operation interface two choices, suitable for different countries of engineering and technical personnel. The recorder equipped large capacity rechargeable lithium battery, display power energy with a three-grid mode, which can continues recording up to 7 days. With the function of system clock and super storage space, it can set the  monitoring and recording time on site, can store 200,000 sets of data, and has the function of setting the interval time of automatic storage, setting from 1 to 99 minutes.

Monitoring software has online real-time monitoring and historical query functions, historical data reading, consulting, saving, reporting and other functions.

The current clamp is made of Permalloy, and adopts CT technology and unique double layer magnetic shielding technology. It is almost unaffected by the external magnetic field, which ensures the uninterrupted monitoring long time with high accuracy, stability and reliability.

Ⅱ. Technical Specification

Functions
online monitoring and recording 1 ~ 3 channel AC leakage current and current, used for circuit insulation fault troubleshooting, monitoring intermittent leakage fault, check the happen time of insulation fault and maintenance lines, etc.
Power source
DC 3.7V rechargeable lithium battery(full charge about 4.2V)
Testing Method
Clamp CT, TRMS
Display Mode
LCD:128dots×64dots
Current Clamp
1-3PCS(Optional)
Instrument Dimension
Host:78mm×165mm ×42mm ; Current clamp 030: 115mm ×70mm×33mm
Weight
Host: 330g ; Current clamp 030: 170g
LCD Dimension
Display field:44mm×27mm
Current Clamp Lead Cable
2 core shield wire, length 2M
Sampling Rate
2 times/second
Data storage
200,000 groups (Power down or replace battery will not lose the data)
Record Period
Set the record interval time within 1 second ~ 99 minutes, 0 seconds is not automatically stored.
Record Time

1,Interval time 1 seconds, can continues recording 48 hours

2,Interval time 10 seconds, can continues recording 120 hours

3,Interval time 1 minute, can continues recording 168 hours

Download Speed
60KB/ Min
Line Voltage
Below AC600V circuit test
Overflow Display
Exceed measure range overflow function: "OL" symbol display
Battery Voltage
Use 3.7V rechargeable lithium battery, power energy display with 3-grid, when the power energy is 0-grid indicate battery voltage is low, please charge in time
Rated Power
In power save mode about 6mA, Max about 35mA
Communication Interface
USB
Record Time
In power save mode continues working 7days
Working Temperature
Working:-10℃~40℃;below 80%rh
Stored Temperature
Storage: -10℃~60℃ ;below 70%rh
Insulation Resistance
100MΩ or larger, 1000V
Suitable Safety Standard
IEC1010-1, IEC1010-2-032, Pollution Class 2, CATⅢ(600V),IEC61326(EMC standard)
Accessories
1,Host,2,Current Clamps 1-3pcs Optional,3,USB/Charge Cable*1,4,Software CD*1,5,Handbag*1,6,Charger*1,7,User Manual

SELECTION GUIDE 1

Clamp on Leakage Current Monitoring Recorder

Click "Blue" marked MODEL NO.to view the spec

ModelRangeResolutionClamp SizeData StorgeChannelsConnection Type
MEWOI9000MEWOI9000.80.jpg
0.0A-500A0.1A35mm×40mm4200SetsSingleWired
MEWOI9000CMEWOI9000C.80.jpg0.00mA-20A0.01mA25mm×30mm4200SetsSingleWired
MEWOI9300BMEWOI OEM/ODM  Instruments Manufacturer0.0A-500A0.1A35mm×40mm200000SetsThree-ChannelsWired
MEWOI9300MEWOI OEM/ODM  Instruments Manufacturer0.00mA-20A0.01mA25mm×30mm20000SetsThree-ChannelsWired
MEWOI9500-130TMEWOI9500-130T.80.01.jpg0.000mA-60.00A1uA25mm×30mm3000Sets
1-8 ChannelsWireless
MEWOI9500-140TMEWOI9500-140T.80.01.jpg0.00mA ~ 300.0A0.01mA35mm×40mm3000Sets1-8 ChannelsWireless
MEWOI9500-168TMEWOI9500-168T.80.jpg0.00mA ~ 1200A0.01mAφ68mm3000Sets1-8 ChannelsWireless


Technical Specification

Functions
Measuring AC leakage current and AC current, monitoring current in real-time manner, locating insulation faults and repairing  electrical lines.
Power source
DC6V, alkaline battery LR03 1.5V×4
Testing Method
Clamp CT, TRMS
Range
0.0A-500A
Resolution
0.1A
Accuracy
±2%±5dgt
Clamp size
35mm×40mm
Instrument Dimension
Tester(L×W×H): 75mm ×170mm ×30mm, Current clamp(L×W×H): 122mm ×70mm ×33mm
Mass
Tester: 410g (battery included),Current clamp: 170g
LCD Dimension
Display field: 44mm×27mm
Shield Type
Type B: Double shielding
Sampling Rate
2 samples/s
Data storage
3900 sets (data loss does not occur after power failure or replacing the battery)
Time Setting
Recording internal adjustable from 1 to 60 min, If set to 0 min, the auto-store function is turned off
Recording Time
Continuously operate for about 10 days at the power-saving mode
Line Voltage
Line with a voltage up to AC600V
Overflow Display
The “OL” symbol is displayed when a measured value is beyond the measurement range
Battery. Voltage
A Low-Battery symbol is displayed and the user should replace the battery with a new one when the battery voltage drops to 4.6V  to 4.8V. In this case, the measured values are still accurate.
Rated Power
about 5mA at the power-saving mode, maximum current consumption: 20mA
Lead Length
2 m
Temperature and Humidity
Working: -20℃~50℃;below 80%rh
Storage: -20℃~50℃;below 70%rh
Insulation Resistance
Higher than 100MΩ, 1000V
Safety Codes
IEC1010-1, IEC1010-2-032, Pollution Class 2, CAT Ⅲ(600V), IEC61326(EMC standard)
Accessories
Tester: 1 PCS, Current clamp: 3PCS, Instrument bag: 1 PCS, RS232 Com-cable:1 PCS; Software Disk: 1 PCS

Tester: 1 PCS, Current clamp: 3PCS, Instrument bag: 1 PCS, RS232 Com-cable:1 PCS; Software Disk: 1 PCS

Telephone
E-mail
After Sales
QQ