Function | On-line monitoring ground resistance, ground voltage, equipotential connection resistance, low resistance. |
Power Supply | Standard: 12V±1VDC, 150mA Max. Optional: 24V±1VDC. |
| Range | Accuracy | Resolution |
Resistance | 0.01Ω~20Ω | ±1%rdg±3dgt (auxiliary ground resistance 100Ω±5%, voltage to ground<10V) | 0.01Ω |
0.1Ω~200Ω | 0.1Ω |
1Ω~2000Ω | 1Ω |
Voltage | 0~600V AC | ±1%rdg±3dgt | 1V |
Measure Mode | Precise 3-wire measurement, simple 2-wire measurement. |
Measure Method | Ground resistance: rated current change-pole method, measured current 3mA Max, 820Hz; Voltage to ground: average value rectification method. |
Data Mode | Mean. |
Display Mode | 4-digital super-large LCD. |
Measuring Indicator | During measurement, LCD count down display. |
LCD Size | 128mm×75mm; Display field: 124mm×67mm. |
Dimension | L×W×H: 190mm×117mm×54mm. |
Measure Rate | Voltage to ground: about 2 times/second; ground resistance: about 30 seconds/time. |
Measure Times | Over 5000 times(Measuring 10Ω for one time and take a pause for 30s). |
Line Voltage | Measuring voltage to ground: measuring below AC 600V. |
Instrument Interface | Pluggable terminal blocks: 9 pin connector. |
Communication Method | RS485 (or optional RS232). |
Communication Line | USB to RS485 communication line( or optionalUSB to RS232 communication line). |
Range Shift | Automatically. |
Data Storage | 400 sets, flash display FULL icon to indicate storage is full. |
Interval Time | Range of automatic monitoring interval time: 1-999 h. |
Data Access | Data read function: READ icon display. |
Overflow Display | Exceeding measuring range overflow function: OL icon display. |
Power Consumption | Backlit : 20mA Max. |
Standby: 25mA Max. |
Measurement: 70mA Max. |
Alarm | Audible and visible alarm. |
Power supply Voltage | When power supply voltage decreases to about 7.8V, will display, reminding to replace the power. |
Weight | Detector: 450g. |
Working Humiture | -10℃~40℃; below 80%rh. |
Storage Humiture | - -20℃~60℃; below 70%rh. |
Overload Protection | Measurement ground resistance: E-P, E-C between each interfaces AC 280V/3 sec. |
Insulation Value | Over 10MΩ(between circuit and enclosure 500V). |
Withstand Voltage | AC 3700V/rms. (Between circuit and enclosure). |
Electromagnetism | IEC61010-4-3,Radio frequency electromagnetic field≤1V/m. |
Applicable Safety Rules | IEC61010-1, IEC1010-2-31, IEC61557-1,5, IEC60529(IP54), Pollution degree 2, CAT III 300V. |
Accessories | Meter*1,Power and Communication Cable*1,Aluminum Mounting Parts, Manual |