Contact Us for Quotation | Email:mewoi@mewoi.com | Whatsapp: +8618620373879 |
Ⅰ.Introduction
Click to download: MEWOI6000 Color Page
Click to download: Selection Map
MEWOI6000 power quality analyzer is a product carefully developed by our company and specially designed for field test of three phases, multi-functional and intelligent, man-machine operation and concise and comprehensive test instrument. It is easy to use, large LCD screen display, high resolution, interface in both Chinese and English, shock-proof shell structure and so on. Can simultaneously measure the 4-channel current (ABC three phase and neutral wire current), 4-channel voltage (ABC three-phase voltage and neutral line voltage to ground), the peak value of current voltage, maximum/minimum value over a period, three-phase imbalance factor, short-time voltage flicker, transformer K factor, active power, reactive power, apparent power, power factor and displacement power factor, active power, reactive power, apparent power, total harmonic distortion and harmonic, etc; Display real-time waveform, harmonic ratio bar charts of current voltage; Dynamically capture instantaneous change of voltage current, monitoring starting current, monitoring the power parameters and generate the alarm list, generate the trend chart for a long time record test data. MEWOI6000 power quality analyzer adopt DSP + ARM double processor architecture, DSP is use for data collection and the processing of algorithm, the ARM is use for the communication protocol and the man-machine interface processing; Analog signal acquisition is by 2 pieces AD7655 of ADI company. Resolution for AD7655 is 16 bit and it is 4 channel synchronous sampling. The highest sampling rate can reach 1 MSPS, to ensure the accuracy of the channel and the information integrity, and wouldn’t miss any transient changes in the grid, can more accurate to detect the transient waveform rising and dropping drastically, and waveform instantaneous interrupt; DSP working frequency is over 200 MHZ, to be able to timely monitoring of the power grid and dynamically adjust the sampling frequency to realize synchronization of power frequency and sampling frequency; Using a 5.6 -inch LCD color screen display, a resolution of 640 dots x 480 dots, with different display color difference between the parameters of phase, waveform, vector diagram, harmonic ratio, the user can be more efficient and more intuitive understand the state of power grid parameters. Built-in flash memory can store 60 group of screenshots at the same time, 150 groups of capture transient voltage/current waveform figure, and 12800 groups of alarm list. Starting current detection model can continuously capture starting current waveform for 100 s. Built-in 2G memory card to store the trend curve record, store all the parameters (including 50 harmonics with 123 power parameters), collect data for once every five seconds, trend curve records can be stored for 300 days. |
Ⅱ.Function Specification
Function | Function specification |
Test Function | 4 channel voltage and the 4 channel current waveform real-time display |
True RMS of voltage and current | |
DC component of Voltage | |
Peak value of current and voltage | |
Minimum/maximum values over a period of time of Current and voltage | |
Phasor diagram display | |
Measurement of harmonic of each phase, up to 50 harmonics | |
Display harmonics ratio of current and voltage of each phase | |
The calculation of total harmonic distortion(THD) | |
Active/reactive/apparent power value and gross of each phase | |
Active/reactive/apparent electric energy value and gross of each phase | |
Calculation of transformer K factor | |
Calculation of COSΦ displacement power factor(DPF) and power factor(PF) | |
Calculation of flicker | |
Calculation of three phase unbalance | |
Function of capture and monitoring | Can monitoring instantaneous change of power grid voltage current parameters, including the voltage fluctuation and flicker, voltage surge, sag and short supply interruption, temporary overvoltage and harmonics. Instruments and can store 150 groups of transient waveform |
Function of starting current monitoring | Can monitor the startup current when electrical equipment is starting, help to correctly design capacity. It can display the trend curve of effective value of starting current, the starting current envelope curve, current voltage waveform of the all eight channel. Monitoring for 100 s, can store each cycle of all waveform curve points within 100 s . |
Function of storage | Can totally record 123 parameters such as the testing parameter of base testing function(Urms、Uthd、Ucf、Uunb、Hz、Vrms、Vthd、Vcf、Vunb、PST、Arms、Athd、Acf、Aunb、KF、W、VAR、VA、PF、Cos φ、Tan φ),50 harmonics of voltage, 50 harmonic of current. Generate trend curve, the interval time of recording is able to set, collect once for 5s and can stored 75days. |
Alarm function | Users can set up 40 groups alarm monitoring project, each group can set different judgments parameters (including 50 harmonics a total of 123 different parameters), can be set different alarm threshold, how long it will take to produce the alarm when over the critical value is can be set, etc. Can store up to a maximum of 12800 set alarm record. |
Screenshots function | In any test page screenshots can store the current screen, automatically records the time and test mode at the same time. Such as save the current voltage wave, harmonic bar charts and phasor diagram, etc. Screenshots can be saved up to 60 groups. |
Communication function | Communicate with computer by USB interface, monitoring software can display waveform of power quality analysis, able to read those has been detected and captured like transient waveform, trend curve record, alarm list, test screenshots, etc. |
Setting function | The user can set the time and date, set the display contrast ratio and brightness, set each corresponding color of each phase line in the instrument |
The connection mode of instruments and the grid type can be set | |
Can select different current clamp and different voltage test strain ratio | |
Can be selected menu in Chinese or English menu | |
Chinese/English help menu | Each phase of the operation may at any time by pressing "help" key for related information |
Technical Specification
1. General specification
Power supply | Rechargeable lithium-ion battery pack 9.6V, 4500mAH , backup charger |
Battery indicator | Battery symbol shows dump energy, When the voltage is too low, automatic shutdown after the 1 minute |
Power consumption | Current consumption of normal test 590mA, continuous working for 6 hours |
Close the LCD low-power monitoring mode170mA, battery continuous working for 20hours | |
Display mode | LCD color screen,640dots×480dots ,5.6 inches, display demo:116mm×88mm |
Instrument dimensions | LxWxT:240mm×170mm×68 mm |
Size of clamp | 008B current clamp:7.5mm×13mm; 040B current clamp:35mm×40mm; 068B current clamp: 68mm×68mm |
Number of channels | 4U/4I |
Line voltage | 1.0V~2000V |
Phase voltage | 1.0V~1000V |
Current | 008B current clamp 10mA~10.0A; |
040 current clamp 0.10A~100A; | |
068B current clamp 1.0A~1000A | |
300F Flexible Coil Current Sensor (with Integrator) : 10A ~ 6000A | |
Frequency | 40Hz~70Hz |
Parameters of electricity | W, VA, var, PF, DPF, cos φ, tan φ |
power parameter | Wh, varh, Vah |
Harmonic | 0~50times |
Total harmonic distortion | 0~50 times, each phase |
Model | Waveform model, harmonic model, Power and power energy mode, Waveform capture mode, Trend chart pattern, alarm mode , Screen mode |
Set number of Transient record | 150sets |
Recode | 300 days(recode 20 sets parameter at the same time, recode one point in 5 seconds) |
Min/Max records | Can be measured maximum minimum value over a period of time |
Warning | 40 different types of parameter selection,12800set warning record |
Phasor diagram display | Automatically |
Capacity of screenshots | 60 |
Language of manual | Chinese and English |
Communication | USB |
Automatically shutdown | At alarm/trend chart records/transient capture mode (pending or ongoing), 5 minutes without keystrokes, monitoring instruments automatically in o low power mode, press any key to activate. |
In other test mode, 15 minutes without keystrokes, prompt automatic shutdown after 1 minute | |
Weight | Host: 1.6KG |
108C current clamps: 170g*4pcs | |
140C Current Clamps: 185g*4pcs | |
168C current clamps: 580g*4pcs | |
400G Flexible Coil Current Clamps(With Integrator):330g*4pcs | |
Test wires and adapter:900g | |
Total weight: 9.2KG(Including packing box) | |
length of test line | Current clamp cable:2M; Voltage Cable: 3M |
Working temperature | -10℃~40℃; below 80%Rh |
Working humidity | -10℃~60℃; below 80%Rh |
Input impedance | Input impedance for the test voltage:1MΩ |
Withstand voltage | Can withstand 3700V / 50Hz sinusoidal ac voltage for 1 minute between Instrument wiring and the shell |
Insulation | Between instrument wiring and shell≥10MΩ |
Structure | Double insulation, vibration-proof jacket with insulation |
Safety rules | IEC 61010 1000V Cat III / 600V CAT IV,IEC61010-031,IEC61326,pollusion 2 |
Accessories | Host:1pcs; Case:1pcs; Current Clamp: 008B,040B,068B 4PCS(3*4=12PCS); Cable:5pcs(yellow, green, red, blue, black ); Alligator clip 5pcs; Pin 5pcs; Charger 1pcs; Soft ware 1pcs; 2Gmemory card(in host) 1pcs. |
2. Accuracy of instruction (under the base condition)
Measurement specification | Range | Display resolution | The maximum error in the range of the reference |
Frequency | 40Hz~70Hz | 0.01Hz | ±(0.03)Hz |
True RMS phase voltage | 1.0V~1000V | Min resolution0.1V | ±(0.5%+5dgt) |
True RMS line voltage | 1.0V~2000V | Min resolution0.1V | ±(0.5%+5dgt) |
DC Voltage | 1.0V~1000V | Min resolution0.1V | ±(1.0%+5dgt) |
True RMS current | 10.0mA~1000A | Min resolution0.1mA | ±(0.5%+5dgt) |
Phase voltage peak | 1.0V~1414V | Min resolution0.1V | ±(1.0%+5dgt) |
Line voltage peak | 1.0V~2828V | Min resolution0.1V | ±(1.0%+5dgt) |
Current peak | 0.0mA~1414A | Min resolution0.1mA | ±(1.0%+5dgt) |
Peak factor | 1.00~3.99 | 0.01 | ±(1%+2dgt) |
4.00~9.99 | 0.01 | ±(5%+2dgt) | |
Active power | 0.000W~9999.9KW | Min resolution 0.001W | ±(1%+3dgt);Cosφ≥0.8 |
±(1.5%+10dgt);0.2≤Cosφ<0.8 | |||
Reactive power Inductive & Capacitive | 0.000VAR~9999.9KVAR | Min resolution 0.001VAR | ±(1%+3dgt);Sinφ≥0.5 |
±(1.5%+10dgt);0.2≤Sinφ<0.5 | |||
Apparent power | 0.000VA~9999.9KVA | Min resolution 0.001VA | ±(1+3dgt %) |
Power factor | -1.000~1.000 | 0.001 | ±(1.5%+3dgt);Cosφ≥0.5 |
±(1.5%+10dgt);0.2≤Cosφ<0.5 | |||
Active energy | 0.000Wh~9999.9MWh | Min resolution 0.001Wh | ±(1%+3dgt);Cosφ≥0.8 |
±(1.5%+10dgt);0.2≤Cosφ<0.8 | |||
Reactive energy Inductive & Capacitive | 0.000VARh~9999.9MVARh | Min resolution 0.001VARh | ±(1%+3dgt);Sinφ≥0.5 |
±(1.5%+10dgt);0.2≤Sinφ<0.5 | |||
Apparent power | 0.000VA~9999.9MVAh | Min resolution 0.001VAh | ±(1%+3dgt) |
Phase angle | -179°~180° | 1° | ±(2°) |
Tan φ(VA≥50VA) | -32.76~32.76 | Min resolution 0.001 | φ:±(1°) |
The displacement power factor (DPF) | -1.000~1.000 | 0.001 | ±(1%+5dgt) |
Harmonicratio(Vrms>50V) | 0.0 %~99.9 % | 0.1 % | ±(1%+5dgt) |
Harmonic Angle(Vrms>50V) | -179°~180° | 1° | ±(3°)harmonic1~25 |
±(10°)harmonic26~50 | |||
Rate of total harmonic (DF or THD-F)≤50 | 0.0 %~99.9 % | 0.1 % | ±(1%+5dgt) |
Distortion factor (DF or THD-R)≤50 | 0.0 %~99.9 % | 0.1 % | ±(1%+10dgt) |
Transformer K factor | 1.00~99.99 | 0.01 | ± (5 %) |
Three-phase imbalance | 0.0%~100 % | 0.1 % | ± (1 %) |
3. Feature of current clamp
Model | True RMS current | Max error True RMS current | Max error of Phase Angle Φ |
MEWOI 108C Ф8mm | 10mA~99mA | ±(1 % + 3dgt) | ±(1.5°),Arms≥20mA |
100mA~10.0A | ±(1 % + 3dgt) | ±(1°) | |
MEWOI 140C Ф40mm | 0.10A~0.99A | ±(1 % + 3dgt) | ±(1.5°) |
1.00A~100A | ±(1 % + 3dgt) | ±(1°) | |
MEWOI 168C Ф68mm | 1.0A~9.9A | ±(2 % + 3dgt) | ±(3°) |
10.0A~1000A | ±(2 % + 3dgt) | ±(2°) | |
MEWOI400G Ф300mm | 10A~99A | ±(1 % + 3dgt) | ±(3°) |
100A~6000A | ±(1 % + 3dgt) | ±(2°) |
Host:1pcs; Case:1pcs; Current Clamp: 008B,040B,068B 4PCS(3*4=12PCS); Cable:5pcs(yellow, green, red, blue, black ); Alligator clip 5pcs; Pin 5pcs; Charger 1pcs; Soft ware 1pcs; 2Gmemory card(in host) 1pcs.