MEWOI1000T-AC 0.0ma-1200A φ48mm Portable Type H/L 60KV Voltage Clamp Current Leaker

Electricity Testing Instruments manufacturer, Support OEM/ODM, your testing specialist

  • Main Features:: 1,current size: 48 mm,2,AC Current:0.0mA~1200A 3,AC Voltage:0.00 V~10KV (automatic shift),4,Data Storage: 99sets
  • Model No.:: MEWOI1000T
  • Name:: MEWOI1000T-AC 0.0mA-1200A φ48mm Portable Type H/L 60KV Voltage Clamp Current Leaker

Contact Us for QuotationEmail:mewoi@mewoi.comWhatsapp: +8618620373879

INTRODUCTION

Click to download:  MEWOI1000T Color Page

Click to download:  MEWOI1000T Manual

MEWOI1000T.800.jpg

MEWOI1000T Portable Type H/L Voltage Clamp Current Leaker has broken through the traditional structure, with 32cm long insulating rod which is specially well-designed for measuring high voltage current, adopting the latest CT technology and integrated mask digital technology, portable design are fit in the measurement of H/L voltage current, leakage current which needs a safety distance. To choose different model can accurately measure 0.1mA -1200A current or leakage current.

MEWOI1000T Portable Type H/L Voltage Clamp Current Leaker has an innovative integrated design between transducer clamp and transducer domain, ensuring the high-precision, high-reliability, and high-stability on constant test perennially. The insulating rod is portability, have the characteristic of damp proof, high temperature resistance, shock resistance, insulating.

MEWOI1000T Portable Type H/L Voltage Clamp Current Leaker with an insulating rod can use to measure the wire without any insulation with voltage below 1kV or convergence generatrix. It can also use to measure the current of the wire with voltage below 10kV and the wire is with insulation layer, online current testing, and have the function of peak holding, data holding, and data storage. Its special Clamp Leaker can make it easier for clamping or evacuating the tested wire through pressing or pulling back the insulation rod, time-saving and fast, widely used in transformer substation, power plant, industrial and mining enterprises as well as the inspection station and electrician maintenance departments for electrical current detection and field electrical operations. It can also replace the H/L voltage transforming ratio tester, that is, to detect the high and low current for primary circuit and secondary circuit separately, and then calculate to conclude the change of high and low pressure.

TECHNICAL SPECIFICATION

Function

High/Low voltage AC current measurement, leakage current measurement, on-line AC current test, load current measurement

Power Supply

DC6V Alkaline Dry Battery (1.5V AAA X 4)

Size of jaw

Φ48mm

range

0.0mA~1200A

Resolution

0.1mA

Test Accuracy(23°C±5°C,Below 80%RH)

0mA~299mA: 1% 5dgt
0.30A~49.9A: 1.5% 5dgt
50.0A~199.9A: 2 5dgt
200A~600A: 3 5dgt
601A~1200A: 4% 5dgt

Frequency of current

50/60Hz Auto Identification

Insulation rod

300mm*3pcs

Test Method

Clamp CT, Integral Method

Display Mode

4 digital LCD display, backlight function, suitable for dark place.

LCD Dimension

47mm×28.5mm

Meter Dimension

76mmx255mmx31mm

Sampling Speed

About 2 times/second

Shift

Automatic Shift

Data Storage

99 Groups, during storage, the symbol “MEM” gives indication, “FULL” mark will flash to indicate the memory has been full.

Circuit Voltage

Test for the bare conductor below 1KV, test the current with insulation layer below 10kV(operated with insulation rod)

Peak Maintenance

Automatically maintain the height of the test value, usually in the test mode pressPEAK key, PEAK lights, that is, to keep open the PEAK function, then press PEAK key to cancel this function

Data Preservation

Under general test mode, press HOLD button to preserve data, “HOLD” symbol display. then press HOLD Key to cancel this function

Data Access

“MR” symbol indicates, it can read the stored data by turning upwards and downwards.

Overflow Display

Exceed measurement range overflow function: “OL A” symbol display

Auto Shut Down

About 15 minutes after booting, the meter will shut down automatically, in order to decrease the battery consumption.

Battery Voltage

When the battery voltage is below 4.8V, the symbol of battery voltage“    ”will show to remind to replace battery.

Weight

Tester: About 335g (Including battery and rod), total quality of meter: about 1.6Kg (including insulation rod and battery.)

Work Temperature and Humidity

-25°C ~40°C; Below 80%Rh

Storage Temperature and Humidity

-20°C ~60°C; Below 70%Rh

Insulation Intension

AC 3700V/rms. (Between insulation rod and clamp core)

Structure

Anti-Dripping Type II

Accessories

Meter:1pc; Meter Box:1pc; Insulation:1pc;Battery(Alkaline Dry Battery AAA):4pc.

MEWOI H/L Voltage Current Clamp Meter Selection Guide(Click the "Blue"Marked model No.to view the Spec)

Model No.Product NameAC RangeDefinitionClamp SizeData StorgeCircuit VoltageOther

MEWOI1000

MEWOI1000.Fluke.80.jpg

H/L Voltage Clamp Meter

AC  0.0mA~

1200A

0.0mA Automatic 

Shift 

φ50mm99setsbelow 60KV(operated with insulation rod,Bare wire35KV)

MEWOI1000C

MEWOI1000C.Extech.80.jpg

Wireless H/L Voltage Clamp Meterwireless(Distance:30M)

MEWOI1000T

MEWOI1000T.Extech.80.jpg

Portable H/L Voltage Clamp Meter

MEWOI1100

MEWOI1100.HIOKI.80.jpg

H/L Voltage Clamp Current MeterAC  0.00mA~600A0.01mAφ33mm99setsbelow 60KV(operated with insulation rod,Bare wire35KV)

MEWOI1100C

MEWOI1100C.Extech.80.jpg

Wireless H/L Voltage Clamp Current MeterAC  0.0mA~1200A0.1mAφ33mm99setsbelow 60KV(operated with insulation rod,Bare wire35KV)wireless(Distance:30M)
MEWOI1100T

MEWOI1100T.HIOKI.80.jpg

Portable H/L Voltage Clamp Current MeterAC  0.00mA~600A0.1mAφ33mm99setsbelow 10KV(operated with insulation rod,Bare wire 1KV)
MEWOI1200

MEWOI1200.Extech.80.jpg

H/L Voltage Clamp Current MeterAC  0.00mA~1000A(0.00mA~1600A Optional)0.01mAφ68mm99setsbelow 60KV(operated with insulation rod,Bare wire35KV)

MEWOI1200C

MEWOI1200C.80.jpg

Wireless H/L Voltage Clamp Current Meter99setswireless(Distance:30M)


APPLICATION

2013111915495276.jpg

TECHNICAL SPECIFICATION

Function

High/Low voltage AC current measurement, leakage current measurement, on-line AC current test, load current measurement

Power Supply

DC6V Alkaline Dry Battery (1.5V AAA X 4)

Size of jaw

Φ48mm

range

0.0mA~1200A

Resolution

0.1mA

Test Accuracy(23°C±5°C,Below 80%RH)

0mA~299mA: 1% 5dgt
0.30A~49.9A: 1.5% 5dgt
50.0A~199.9A: 2 5dgt
200A~600A: 3 5dgt
601A~1200A: 4% 5dgt

Frequency of current

50/60Hz Auto Identification

Insulation rod

300mm*3pcs

Test Method

Clamp CT, Integral Method

Display Mode

4 digital LCD display, backlight function, suitable for dark place.

LCD Dimension

47mm×28.5mm

Meter Dimension

76mmx255mmx31mm

Sampling Speed

About 2 times/second

Shift

Automatic Shift

Data Storage

99 Groups, during storage, the symbol “MEM” gives indication, “FULL” mark will flash to indicate the memory has been full.

Circuit Voltage

Test for the bare conductor below 1KV, test the current with insulation layer below 10kV(operated with insulation rod)

Peak Maintenance

Automatically maintain the height of the test value, usually in the test mode pressPEAK key, PEAK lights, that is, to keep open the PEAK function, then press PEAK key to cancel this function

Data Preservation

Under general test mode, press HOLD button to preserve data, “HOLD” symbol display. then press HOLD Key to cancel this function

Data Access

“MR” symbol indicates, it can read the stored data by turning upwards and downwards.

Overflow Display

Exceed measurement range overflow function: “OL A” symbol display

Auto Shut Down

About 15 minutes after booting, the meter will shut down automatically, in order to decrease the battery consumption.

Battery Voltage

When the battery voltage is below 4.8V, the symbol of battery voltage“    ”will show to remind to replace battery.

Weight

Tester: About 335g (Including battery and rod), total quality of meter: about 1.6Kg (including insulation rod and battery.)

Work Temperature and Humidity

-25°C ~40°C; Below 80%Rh

Storage Temperature and Humidity

-20°C ~60°C; Below 70%Rh

Insulation Intension

AC 3700V/rms. (Between insulation rod and clamp core)

Structure

Anti-Dripping Type II

Accessories

Meter:1pc; Meter Box:1pc; Insulation:1pc;Battery(Alkaline Dry Battery AAA):4pc.

Meter:1pc; Meter Box:1pc; Insulation Rod:3pcs;Battery(Alkaline Dry Battery AAA):4pc.

Telephone
E-mail
After Sales
QQ