MEWOI1200- AC 0.00mA~1000A 60KV Φ68mm H/L Voltage Clamp Current Meter

OEM/ODM Instruments Manufacturer

  • Main Features:: 1,AC current detection 2, Range: AC 0.00mA~1000A 3,clamp size:φ68mm
  • Model No.:: MEWOI1200
  • Name:: MEWOI1200- AC 0.00mA~1000A 60KV Φ68mm H/L Voltage Clamp Current Meter

Contact Us for QuotationEmail:mewoi@mewoi.comWhatsapp: +8618620373879

INTRODUCTION

Click to download:  MEWOI1200 Color Page

Click to download:  MEWOI1200 Manual

MEWOI1200.801.jpg

MEWOI1200 H/L Voltage Clamp Current Meter has broken through the traditional structure, which is specially well-designed for measuring high voltage current, adopt latest CT technology and integrated mask digital technology, composed of special clamp current meter and high voltage insulation rods. Without insulation rods, it can used as high-precision low-voltage clamp meter and leakage current meter, can accurately measure the current or leakage current of 0.01mA.

MEWOI1200 H/L Voltage Clamp Current Meter adopt hook type structure of innovation, which can hook the line to test, save the physical power of user, to ensure the high precision , high stability and high reliability of perennial uninterrupted measurement.
 The rods of MEWOI1200 H/L Voltage Clamp Current Meter can be used for   insulating sheath wires(≤60kV)and bare wire (≤35kV) high voltage line current measurement and online current measure below 60kV,also with the factions of peak value holding, data holding, data storage and wireless transmission , etc. It is easy to clamp or disconnect the wire by pulling-down or forwarding the insulation rods of the special clamp current meter, with the advantages of safely and time-saving. Widely used in power plant, substation industrial and mining enterprise, inspection station, electrician maintenance department for current sensing and field working. t can also be used as high and low voltage changing ratio tester , that is, respectively test the first loop and secondary loop high and low voltage change through manually calculation . The insulation rod is light and convenient, with the advantages of anti-moisture, high temperature resistance, anti-impact , bending resistance , high insulation , flexibility and other characteristics.

TECHNICAL SPECIFICATION

Function
H-voltage AC current measure,L-voltage AC /leakage current measure
AC current monitor online
Power Supply
DC6V Alkaline Dry Battery(1.5V AAA X 4)
Test Method
Clamp CT, Integral Method;hook the meter on the line to test,save the physical power of user.
Clamp Diameter
Φ68mm
Range of measurement
0.00mA~1000A(50Hz/60Hz Automatic) 0.00mA~1600A Optional
Resolution
0.01mA
Shift
0.00mA~1000A Automatic Shift
Test Accuracy (23℃±5℃,≤80% RH)
0.00mA~299mA: ±1%±3dgt 
0.30A~49.9A: ±1.5%±5dgt 
50.0A~199.9A: ±2%±5dgt
200A~600A:    ±3%±5dgt   
601A~1000A:   ±4%±5dgt  
Display Mode
4 digital LCD display
LCD Dimension
Tester: LCD: 35mm×21.5mm
Meter Dimension
Tester: 218mm×135mm×60mm
Sampling Speed
About 2 times/second
Data Storage
99 Groups,during storage, the symbol “MEM” gives indication, “FULL” mark will flash to indicate the memory has been full.
PEAk Maintenance
Automatically maintain the height of the test value,usually in the test mode pressPEAK,LCD top right corner will display “PE”,that is, to keep open the PEAK function, then press PEAK key to cancel this function key
Circuit Voltage
Test insulating sheath wires(≤60kV)and bare wire t( ≤35kV)
 (operated with insulation rod)
Data Preservation
Under general test mode, press HOLD button to preserve data, “DH” symbol display. then press HOLD Key to cancel this function
Data Access
“MR” symbol indicates, it can read the stored data by turning upwards and downwards.
Overflow Display
Exceed measurement range overflow function: “OL A” symbol display
Auto Shut Down
About 15 minutes after booting, the meter will shut down automatically, in order to decrease the battery consumption.
Battery Voltage
When the battery voltage is below 4.8V, the symbol of battery voltage“    ”will show to remind to replace battery.
Weight
Tester:About 620g (Including battery)
Total quality of meter: about 2.3kg(including insulation rod and battery)
Work Temperature and Humidity
-10℃ ~ 40℃; ≤80%Rh
Storage Temperature and Humidity
-10℃ ~ 60℃; ≤70%Rh
interference
No same frequency interference of 315MHz and 433MHz
Insulated Rod Dimension
Φ32mm, 1m/ Section(5 Sections)
Insulation Intension
Tester: AC 2kV/rms(Between core and shell)
Insulating rod: AC 100kV/rms(5 sections insulating rod all connections, between both ends)
Structure
Anti-Dripping Type II
accessories
Tester:1set;meter box: 1 pcs; Insulating rod (1m): 5 sections.

MEWOI H/L Voltage Current Clamp Meter Selection Guide(Click the "Blue"Marked model No.to view the Spec)

Model No.Product NameAC RangeDefinitionClamp SizeData StorgeCircuit VoltageOther

MEWOI1000

MEWOI1000.Fluke.80.jpg

H/L Voltage Clamp Meter

AC  0.0mA~

1200A

0.0mA Automatic 

Shift 

φ50mm99setsbelow 60KV(operated with insulation rod,Bare wire35KV)

MEWOI1000C

MEWOI1000C.Extech.80.jpg

Wireless H/L Voltage Clamp Meterwireless(Distance:30M)

MEWOI1000T

MEWOI1000T.Extech.80.jpg

Portable H/L Voltage Clamp Meter

MEWOI1100

MEWOI1100.HIOKI.80.jpg

H/L Voltage Clamp Current MeterAC  0.00mA~600A0.01mAφ33mm99setsbelow 60KV(operated with insulation rod,Bare wire35KV)

MEWOI1100C

MEWOI1100C.Extech.80.jpg

Wireless H/L Voltage Clamp Current MeterAC  0.0mA~1200A0.1mAφ33mm99setsbelow 60KV(operated with insulation rod,Bare wire35KV)wireless(Distance:30M)
MEWOI1100T

MEWOI1100T.HIOKI.80.jpg

Portable H/L Voltage Clamp Current MeterAC  0.00mA~600A0.1mAφ33mm99setsbelow 10KV(operated with insulation rod,Bare wire 1KV)
MEWOI1200

MEWOI1200.Extech.80.jpg

H/L Voltage Clamp Current MeterAC  0.00mA~1000A(0.00mA~1600A Optional)0.01mAφ68mm99setsbelow 60KV(operated with insulation rod,Bare wire35KV)

MEWOI1200C

MEWOI1200C.80.jpg

Wireless H/L Voltage Clamp Current Meter99setswireless(Distance:30M)

APPLICATION

20114184934732.jpg

TECHNICAL SPECIFICATION
Function
H-voltage AC current measure,L-voltage AC /leakage current measure
AC current monitor online
Power SupplyDC6V Alkaline Dry Battery(1.5V AAA X 4)
Test MethodClamp CT, Integral Method;hook the meter on the line to test,save the physical power of user.
Clamp DiameterΦ68mm
Range of measurement0.00mA~1000A(50Hz/60Hz Automatic)
Resolution0.01mA
Shift0.00mA~1000A Automatic Shift
Test Accuracy (23℃±5℃,≤80% RH)0.00mA~299mA: ±1%±3dgt 
0.30A~49.9A: ±1.5%±5dgt 
50.0A~199.9A: ±2%±5dgt
200A~600A:    ±3%±5dgt   
601A~1000A:   ±4%±5dgt  
Display Mode4 digital LCD display
LCD DimensionTester: LCD: 35mm×21.5mm
Meter DimensionTester: 218mm×135mm×60mm
Sampling SpeedAbout 2 times/second
Data Storage99 Groups,during storage, the symbol “MEM” gives indication, “FULL” mark will flash to indicate the memory has been full.
PEAk MaintenanceAutomatically maintain the height of the test value,usually in the test mode pressPEAK,LCD top right corner will display “PE”,that is, to keep open the PEAK function, then press PEAK key to cancel this function key
Circuit Voltage
Test insulating sheath wires(≤60kV)and bare wire t( ≤35kV)
 (operated with insulation rod)
Data PreservationUnder general test mode, press HOLD button to preserve data, “DH” symbol display. then press HOLD Key to cancel this function
Data Access“MR” symbol indicates, it can read the stored data by turning upwards and downwards.
Overflow DisplayExceed measurement range overflow function: “OL A” symbol display
Auto Shut DownAbout 15 minutes after booting, the meter will shut down automatically, in order to decrease the battery consumption.
Battery VoltageWhen the battery voltage is below 4.8V, the symbol of battery voltage“    ”will show to remind to replace battery.
Weight
Tester:About 620g (Including battery)
Total quality of meter: about 2.3kg(including insulation rod and battery)
Work Temperature and Humidity-10℃ ~ 40℃; ≤80%Rh
Storage Temperature and Humidity-10℃ ~ 60℃; ≤70%Rh
interferenceNo same frequency interference of 315MHz and 433MHz
Insulated Rod DimensionΦ32mm, 1m/ Section(5 Sections)
Insulation Intension
Tester: AC 2kV/rms(Between core and shell)
Insulating rod: AC 100kV/rms(5 sections insulating rod all connections, between both ends)
StructureAnti-Dripping Type II
accessoriesTester:1set;meter box: 1 pcs; Insulating rod (1m): 5 sections.

Tester:1set;meter box: 1 pcs; Insulating rod (1m): 5 sections.

Telephone
E-mail
After Sales
QQ