Earth Resistance Testers Guide
Contact Us for Quotation | Email:mewoi@mewoi.com | Whatsapp: +8618620373879 |
SELECTION GUIDE
Digital Earth Resistance Clamp Meter
Click "blue"marked model No. for detailed Specificaiton
Model | Range | Resolution | clamp size | RS232 | Data Storge | Other |
0.01Ω-200Ω | 0.001Ω | 65mm×32mm | optional | 99sets | ||
ø32mm | ||||||
MEWOI3000B | 55mm×32mm | |||||
MEWOI3000 | 0.01Ω-1000Ω | 0.001Ω | 55mm×32mm | 99sets | ||
0.01Ω-1200Ω | 0.001Ω | 65mm×32mm | optional | 99sets | ||
ø32mm | ||||||
MEWOI3000D | 0.01Ω-1000Ω 0.00-30.00A | 0.001Ω,0.05mA | 55mm×32mm | 99sets | ||
0.01Ω-1200Ω 0.00-20.00A | 0.001Ω,0.05mA | 65mm×32mm | optional | 99sets | ||
ø32mm | ||||||
0.01Ω-1500Ω 0.00-40.00A | 0.001Ω,0.05mA | 65mm×32m m | √ | 99sets | Rechargable Batteries | |
0.01Ω-100Ω | 0.01Ω | 60mm*30mm,(Closed) | Appoint with RS485 communication interface, provide standard MODBUS-RTU communication protocol | × | ||
0.01Ω-100Ω | 0.01Ω | 60mm*30mm (Closed), | × | LCD display,warning function. | ||
0.01Ω-200Ω | 0.01Ω | Split Type 56mm×26mm | Wired network: RS232,RS485 standard communication protocol Wireless network: RS232、RS485、GSM communication protocol | × | ||
0.01Ω-200Ω | 0.01Ω | Split Type 56mm×26mm | × | LCD display,warning function. | ||
0.01Ω~2000Ω | 0.01Ω | 2/3-wires measurement, Online | ||||
0.01Ω~2000Ω | 0.01Ω | 2/3-wires measurement, Online,GPRS | ||||
0.01Ω~2000Ω; 0~600V | 0.01Ω,1V | √ | 400sets | 2/3-wires measurement of earth resistance/voltage | ||
0.01Ω~2000Ω; 0~600V | 0.01Ω,1V | √ | 400sets | 2/3-wires measurement of earth resistance/voltage | ||
earth resistance:0.01Ω~30.00KΩ; soil resistivity:0.01Ωm~9000KΩm; 0~600V | 0.01Ω,0.01Ωm,1V | √ | 300sets | 2/3/4-wires measurement of earth resistance,soil resistivity,and earth voltage | ||
MEWOI4200D | earth resistance:0.01Ω~30.00KΩ; soil resistivity:0.01Ωm~9000KΩm; 0~600V | 0.01Ω,0.01Ωm,1V | √ | 300sets | 2/3/4-wires measurement of earth resistance,soil resistivity,and earth voltage | |
earth resistance:0.01Ω~30.00KΩ;AC Leakage current: 0.00mA~600A; soil resistivity:0.01Ωm~9000KΩm;Earth Voltage:0.0~100.0V,dual clamp: 0.01Ω-100Ω | 0.01Ω,0.01Ωm,0.01A,0.1V | ø68mm | √ | 2000sets | 2/3/4-wires,selection & dual clamp method to measure the earth resistance,soil resistivity,earth voltage,AC voltage,AC leakage current,warning function. | |
earth resistance:0.01Ω~30.00KΩ;AC Leakage current: 0.00mA~600A; soil resistivity:0.01Ωm~9000KΩm;Earth Voltage:0.0~100.0V,dual clamp: 0.01Ω-100Ω | 0.01Ω,0.01Ωm,0.01A,0.1V | ø68mm | √ | 2000sets | 2/3/4-wires,selection & dual clamp method to measure the earth resistance,soil resistivity,earth voltage,AC voltage,AC leakage current,warning function. | |
Ground resistance:0.10Ω ~ 200Ω(4 clamp method) Ground resistance ( R ):0.10Ω ~ 20KΩ Soil resistivity ( ρ )0kΩm~9000kΩm AC current (A~)1mA~500.0A Ground voltage (V~)0.0V~200.0V | 0.01Ω,0.01Ωm,0.01mA,0.1V | ø68mm | √ | 100sets | Untie-free tower grounding resistance tester |