Contact Us for Quotation | Email:mewoi@mewoi.com | Whatsapp: +8618620373879 |
MEWOI2500 Wireless High Voltage Phase Detector
INSTRUCTION
MEWOI2500 Wireless High Voltage Phase Detector is specially designed and manufactured for high voltage line and high voltage switchgear (middle cabinet, ring network cabinet, etc.) nuclear phase, the instrument breaks through the traditional nuclear phase device voltage grade limit problem, can be in the very low voltage line nuclear phase, completely realize from 10V to 500kV voltage automatic nuclear phase. Adopt wireless transmission technology, phase detecting distance 200m, phase detecting accurately, operation convenient. Adopt 3.5inch LCD color screen can display the phase, frequency, phase sequence, and phase detecting results on the same screen. The dynamic vector diagram indication, clear and obvious.Adopt 3.5inch LCD color screen can display the phase, frequency, phase sequence, and phase detecting results on the same screen. The dynamic vector diagram indication, clear and obvious. MEWOI2500 Wireless High Voltage Phase Detector is composed of host, detector, telescopic insulating rod, monitoring software, USB communication line and so on. The host adopts 3.5-inch LCD color screen, which can display phase, frequency, phase sequence and nuclear phase result on the same screen. With Voice prompt: "X signal is normal, Y signal is normal, same phase, out phase"Monitoring software has the functions of online real-time monitoring, historical data query, vector graph indication, and phase indication; it has functions such as historical data reading, viewing, saving, and printing. |
SPECIFICATION
Functions | phase detecting of high voltage line and high voltage switchgear (centrally installed switchgear, ring main unit, etc.),testing of frequency, phase, phase sequence and electricity testing |
Power Supply | Host: DC 9V alkaline battery LR6X6PCS Detector: DC4.5V, LR6X3PCS |
Phase Detecting Mode | Contact phase detecting: ≤35kV line. Non-contact: ≥10kV and ≤35kV, it can phase detecting on the insulation skin of the cable; when the line voltage>35KV, it must adopt non-contact phase detecting |
Phase Detecting Voltage | 10V~500KV |
Transmission Distance | 200 Meters |
Phase Qualitative | Same phase : -20°~20° Out phase: 100°~140° and 220°~260° |
Range | Test phase: 0.0°~360.0° |
Test frequency: 45.0Hz~65.0Hz | |
Accuracy | Phase: ≤±8° |
Frequency: ≤±2Hz | |
Resolution | Phase: 1°; Frequency: 0.1Hz |
Transmitting Frequency | 433MHz、315MHz |
LCD Size | 3.5 inch color screen; display area: 71mm×53mm |
Phase Indication | Vector diagrams and figures are displayed simultaneously |
Power Indication | The detector equip with green power indicator |
Electricity Testing Indication | “Bee--bee-bee” buzzer sound |
Voltage Display Range | 0.1kV~35kV |
Display Speed Rate | 2 times/second |
Data Storage | 200 groups(power down or replace battery will not lose data) |
Automatic Shut Down | 15 minutes after boot up, the meter shuts down automatically without any operation |
Battery Voltage | When the battery voltage is lower than 8.1V±0.1V, low battery voltage symbol will display, remind to replace battery, the measurement data are also accurate at this moment |
Rated Current | Detector: 30mA Max; Host: 150mA Max |
Instrument Weight | Instrument: 950g; Package and insulation rod total weight: 3.0KG |
Instrument Size | Host: 195mm×100mm×45mm; Detector: 130mm×65mm×45mm |
Insulation Rod Length | Max φ45mm, Contraction state: 1000mm; Stretched state: 4500mm. |
Insulation Test | The insulation rod stretched to both ends: AC 220 kV / rms Host, detector: AC3700V / rms (between exposed metal and plastic shell) |
External Interference | No extremely strong electromagnetic fields, No 315MHz, 433MHz same-frequency signal interference |
Working Temperature | -10℃~40℃;Below 80%rh |
Storage Temperature | -10℃~60℃;Below 70%rh |
Protection Level | IP63 |
Suitable Safety Standard | GB13398-92、GB311.1-311.6-8、3DL408-91,《General technical requirements for portable nuclear power apparatus for use in 1kV ~ 35kV portable power plants DL/T971-2005》 IEC61481-A2;2004;IEC 61243-1 ed.2:2003 |
Accessoires | Host:1set, Detector: 2 pieces, Probe: 2pcs, Probe Hook: 2pcs,insulation rod: 2pcs, 1 piece of software CD, 1 piece of USB data cable, 6 pieces of LR6 battery, 2 pieces of 6F22 battery, 1 inspection line, Toolkit 1 piece |
Selection Guide:
Model No.: | Name | Measure Range | Phase Detecting Distance | Phase Range | Frequency Range | Data Storage |
MEWOI2600 | Wireless High Voltage Phase Detector | AC 200V~220kV | 60m | 0.0°~360.0° | 45.0Hz-65.0Hz | 9999sets |
Wireless High Voltage Phase Detector | AC 10V-500KV | 200m | 0.0°~360.0° | 45.0Hz-65.0Hz | 200sets |
SPECIFICATION
Functions | High-voltage phase detect, frequency, phase, phase sequence, electrical inspection. |
Power Supply | Host: DC9V,6pcs 5 alkaline batteries,Detector:Zinc - manganese dry batteries 6F22、9V |
Phase Detect Modes | 1.Contact Phase Detect: can contact wire which is below 35KV(bare wire)or 220KV(With insulation Cover) 2.Non-Contact Phase Detect: conduct non-contact testing when bare wire exceeds 35KV,detect Probe close to the wire gradually. |
Wireless Distance | 30M |
Phase characterization | 1.In Phase:-25°~25° 2.Out of Phase: 95°~145° and 215°~265 |
Phase detect Voltage | 200V~220kV |
Phase Range | 0.0°~360.0°;Accuracy:≤±12°;Definition:0.1° |
Frequency Range | 45.0Hz~65.0Hz;Accuracy:≤±2Hz;Definition:0.1Hz |
Transmission frequency | 433MHz、315MHz |
LCD | 3.5inch Color Display;Display Field:71mm×53mm |
Phase indication | Phasor diagram and digital display |
Power indication | Green indication light |
Working indication | Sound and Light Indicator,red double flash indicator and "beep - beep - beep" beep sound |
Display Speed | 2Times/Second |
Data Storage | 9999Sets (Replace the battery without losing data) |
LCD backlight | Adjustable brightness, to adapt to different environments |
Automatic shut-down | Turn on the instrument for about 5 minutes |
Battery Voltage | When the battery voltage dropped to 7.2V ± 0.1V, "the battery voltage is low" symbol display, to remind the replacement of the battery, the measured data is also accurate. |
Rated current | Detector:30mA max;Host:150mA max |
Weight | Host:950g(includes Batteries),Packing and Insulation Rod: 3KG |
Size | Host:195mm×100mm×45mm;Detector:290mm×250mm×80mm |
Insulation Rod Length | Max Diameter:Φ38mm;Length:Pull Back 1050mm;Extech 4850mm |
Insulation Test | Insulated rods at both ends after drawing: AC 220 kV / rms Host, detector: AC3700V / rms (exposed metal and plastic housing) |
Outside Interference | No special strong electromagnetic field; no 433MHz, 315MHz frequency interference |
Working Temperature and Humidity | -10℃~40℃; below 80%rh |
Storage Temperature and Humidity | -20℃~60℃; below 70%rh |
Degree of protection | IP63 |
Safety Protocol | GB13398-92、GB311.1-311.6-8、3DL408-91,《General technical requirements for portable nuclear power apparatus for use in 1kV ~ 35kV portable power plants DL/T971-2005》,IEC61481-A2;2004;IEC 61243-1 ed.2:2003 |
Accessories | Host:1set, Detector: 2 pieces, Probe: 2pcs, Probe Hook: 2pcs,insulation rod: 2pcs, 1 piece of software CD, 1 piece of USB data cable, 6 pieces of LR6 battery, 2 pieces of 6F22 battery, 1 inspection line, Toolkit 1 piece |
Host:1set, Detector: 2 pieces, Probe: 2pcs, Probe Hook: 2pcs,insulation rod: 2pcs, 1 piece of software CD, 1 piece of USB data cable, 6 pieces of LR6 battery, 2 pieces of 6F22 battery, 1 inspection line, Toolkit 1 piece