MEWOI8300 Large Caliber Three Phase Leakage Current AMP/VOLT Clamp On Power Tester

Electricity Testing Instruments manufacturer, Support OEM/ODM, your testing specialist

INTRODUCTION

Click to download: MEWOI8300 ColorPage

Click to download: MEWOI8300 Manual

Click to download: Selection MapMEWOI8300.581.jpg

MEWOI8300 Large Caliber Three Phase Leakage Current AMP/VOLT Clamp On Power Tester is well designed and manufactured for measuring three phase AC voltage, current, leakage current, phase between current and voltage, phase between phase voltage, frequency, power energy, phase sequence, active power, reactive power, apparent power, power. It is a multifunctional, digital, intelligent tester. Its large caliber 80mm×80mm can clamp electric cable of 80mm diameter, or 96mm×4mm flat cable and steel earth wires. It has all the functions of Large Caliber Leakage Clamp Meter and Micro Power Clamp Meter. Besides, it also has this functions such as distinguish transformer wiring group, inductive and capacitive circuits, test second circuit and bus differential protection systems, read the phase relationship between CTs of the differential protection, check the meter wiring right, repair lines and equipment, etc. Provide operators with a safe, accurate and convenient tester.

MEWOI8300 Large Caliber Three Phase Leakage Current AMP/VOLT Clamp On Power Tester’s clamp core is made of special alloy, adopt the latest magnetic shielding techniques, can almost shield the influence from external magnetic field, to ensure the high precision, high stability and high reliability of perennial uninterrupted measurement. The meter can store 200 sets of data, with RS232 interface, upload stored data to the computer through the system software, implementing online real-time monitoring, historical inquires, dynamic display. With the function of historical data read, export, print, and backlight, data hold, etc. It is a necessary tool for electrical safety testing.

TECHNICAL SPECIFICATION

Function
Measure three phase AC voltage, leakage current, current, active power, reactive power, apparent power, power, phase between current and voltage, phase between phase voltage, frequency, power energy, phase sequence
Power
6V DC(LR6×4 alkaline dry batteries, continuously working for 12 hours)
Test Mode
Clamp CT, integral mode
Clamp Size
80mm×80mm(can clamp electric cable of 80mm diameter, or 96mm×4mm flat cable and steel earth wires)
Current Range
AC 0.00mA-1200A, Resolution: 0.01mA
Power Range
AC 0.5W-720KW, Resolution: 0.01W
Voltage Range
AC 0-600V, Resolution: 0.01V
Frequency Range
25Hz-100Hz, Resolution: 0.1Hz
Phase Range
0.0°-360.0°, Resolution: 0.1°
Power Factor Range
0.3-1.0(Capacitive or inductive) , Resolution: 0.001
Power Energy Range
0.0000KWh-72000KWh, Resolution: 0.0001KWh
Measured Wire Position
Measured wire at approximately the geometric center of the clamp
Data Storage
200 sets,  “FULL the memory is full ” symbol indicate
RS232 Interface
With RS232 interface, download data to computer for analysis and management
Communication Wire
RS232 communication wire, 1.8m
Frequency
50Hz ,60Hz automatic identification
Gear Shift
Automatic shift
Sample Rate
About 2 times/second
Line Voltage
Below AC 600V line measurement
Display Mode
LCD: 128dots×64dots; Display area: 43mm×29mm
Meter Size
Length 275mm × Width 145mm × Height 40mm
Backlight
Controlled by “ *" key
Data Hold
"HOLD" symbol appears
Overflow
"OL" symbol appears
Automatic Shutdown
Automatically shutdown about 15 minutes after power on to reduce battery consumption
Voltage Detection
Low battery symbol  appears to remind the replacement of battery when the battery voltage drops below 5.2V.
Weight
1kg(with batteries and accessories)
Working Current
50mA with enabled backlight; 25mA with disabled backlight
Working Temperature and Humidity
-10℃-40℃; 80%rh
Storage Temperature and Humidity
-10℃-60℃; below 70%rh
Insulation strength
AC 3700V/rms(between core and shell)
SafetySpecifications
IEC1010-1, IEC1010-2-032, 2 class of pollution, CAT Ⅲ(600V)
Accessories
Meter: 1 PC; Test Wires: 4 PCS (Yellow, Green, Red, Black), RS232 Data Wires: 1PC; Disk: 1 PC; Battery(LR6): 4PCS; Meter Box: 1 PC

SELECTION GUIDE 1 

Large Caliber Three Phase Leakage Current AMP/VOLT Clamp On Power Tester

(Click "Blue" Marked Model No. To View The Spec)

Model No.RangeResolutionPower RangeFrequency RangeClamp SizeRS232 InterfaceData Stroge
MEWOI8300MEWOI8300.80.jpg

0.00mA

-1200A,

0.00V-

600V,

0.01mAAC 0.5W-720KW25Hz-100Hz80*80mm
200sets
MEWOI8300BMEWOI8300B.80.jpg

0.0A

-2000A,

0.00V-600V,

0.1AAC 0.5W-1200KW25Hz-100Hz80*80mm200sets

APPLICATION

MEWOI Application.jpg

SELECTION GUIDE 2 

Large Caliber Leakage Clamp Meter

Click "Blue"marked Model No. to View the Spec

Model
RangeResolutionClamp Size
LCD DisplayData Storage
RS232
MEWOI8000MEWOI8000C.80.jpg
AC 0.00mA~1200A, 0~600V0.01mA,0.01V80*80mm99 sets
MEWOI8000BMEWOI8000B_副本.30.jpg
AC 0.00mA~2000A, 0~600V0.01mA, 0.01V80*80mm99 sets
MEWOI8000CMEWOI8000C_副本.80.jpg

AC 0.0A~2500A,0~600V

0.0A, 0.01V80*80mm99 sets
MEWOI8100MEWOI8100_副本.80.jpg
AC 0.0mA~3200A, 0.00~600V0.1mA, 0.01V108*148mm99 sets
MEWOI8100BMEWOI8100B_副本.80.jpg

AC

0.0A~4000A, 0.00~600V

0.1A, 0.01V108*148mm99 sets
MEWOI8100EMEWOI8100E.80.jpg

DC0.0A~2000A,

AC 0.0A~1000A, 0.00~600V

0.1A, 0.01V108*148mm99 sets
 TECHNICAL SPECIFICATION
Function
Measure three phase AC voltage, leakage current, current, active power, reactive power, apparent power, power, phase between current and voltage, phase between phase voltage, frequency, power energy, phase sequence
Power
6V DC(LR6×4 alkaline dry batteries, continuously working for 12 hours)
Test Mode
Clamp CT, integral mode
Clamp Size
80mm×80mm(can clamp electric cable of 80mm diameter, or 96mm×4mm flat cable and steel earth wires)
Current Range
AC 0.00mA-1200A, Resolution: 0.01mA
Power Range
AC 0.5W-720KW, Resolution: 0.01W
Voltage Range
AC 0-600V, Resolution: 0.01V
Frequency Range
25Hz-100Hz, Resolution: 0.1Hz
Phase Range
0.0°-360.0°, Resolution: 0.1°
Power Factor Range
0.3-1.0(Capacitive or inductive) , Resolution: 0.001
Power Energy Range
0.0000KWh-72000KWh, Resolution: 0.0001KWh
Measured Wire Position
Measured wire at approximately the geometric center of the clamp
Data Storage
200 sets,  “FULL the memory is full ” symbol indicate
RS232 Interface
With RS232 interface, download data to computer for analysis and management
Communication Wire
RS232 communication wire, 1.8m
Frequency
50Hz ,60Hz automatic identification
Gear Shift
Automatic shift
Sample Rate
About 2 times/second
Line Voltage
Below AC 600V line measurement
Display Mode
LCD: 128dots×64dots; Display area: 43mm×29mm
Meter Size
Length 275mm × Width 145mm × Height 40mm
Backlight
Controlled by “ *" key
Data Hold
"HOLD" symbol appears
Overflow
"OL" symbol appears
Automatic Shutdown
Automatically shutdown about 15 minutes after power on to reduce battery consumption
Voltage Detection
Low battery symbol  appears to remind the replacement of battery when the battery voltage drops below 5.2V.
Weight
1kg(with batteries and accessories)
Working Current
50mA with enabled backlight; 25mA with disabled backlight
Working Temperature and Humidity
-10℃-40℃; 80%rh
Storage Temperature and Humidity
-10℃-60℃; below 70%rh
Insulation strength
AC 3700V/rms(between core and shell)
SafetySpecifications
IEC1010-1, IEC1010-2-032, 2 class of pollution, CAT Ⅲ(600V)
Accessories
Meter: 1 PC; Test Wires: 4 PCS (Yellow, Green, Red, Black), RS232 Data Wires: 1PC; Disk: 1 PC; Battery(LR6): 4PCS; Meter Box: 1 PC

Meter: 1 PC; Test Wires: 4 PCS (Yellow, Green, Red, Black), RS232 Data Wires: 1PC; Disk: 1 PC; Battery(LR6): 4PCS; Meter Box: 1 PC

Telephone
E-mail
After Sales
QQ