Contact Us for Quotation | Email:mewoi@mewoi.com | Whatsapp: +8618620373879 |
MEWOI-HY106 high Precision Personal Noise Dosimeter,personal sound exposure meter,Dosímetro de Ruídos Digital Portátil de Duplo Canal
Click to download: MEWOI-HY106 high Precision Personal Noise Dosimeter Specification
INTRODUCTION
MEWOI-HY106 personal sound exposure meter is a pocket full digital time weighted integral sound level meter. Its performance meets the requirements of GB / T 15952-2010 and IEC 61252:2002, and its performance level is equivalent to the level 2 sound level meter meeting the requirements of GB / T 3785.1-2010 electroacoustic sound level meters Part 1: specifications. Hy106 personal sound exposure meter is suitable for monitoring various environmental noise and machine noise, especially for noise measurement and analysis of industrial health noise evaluation and occupational workers' hearing protection. |
MEWOI-HY106 Series Personal Sound Exposure Meter
Type | Performance Level | Microphone Type | Measurement Range | 1/1octave band filter | 1/3 octave band filter |
MEWOI-HY106 | Class 2 | 12.7mm | 30dBA~130dBA | × | × |
MEWOI-HY106A(Configuration 1) | Class 2 | 12.7mm | 30dBA~130dBA | √ | × |
MEWOI-HY106B(Configuration 2) | Class 2 | 12.7mm | 30dBA~130dBA | × | √ |
MEWOI-HY106C(Configuration 3) | Class 2 | 6.35mm | 60dBA~145dBA | × | × |
MEWOI-HY106D(Configuration 4) | Class 2 | 6.35mm | 60dBA~145dBA | √ | × |
MEWOI-HY106E(Configuration 5) | Class 2 | 6.35mm | 60dBA~145dBA | × | √ |
MEWOI-HY106 Main Features and Functions:
1,Performance grade: equivalent to the class 2 sound level meter conforming to gb/t 3785.1-2010 electroacoustic sound level meter part 1: specification. |
2,Microphone: Class 2 Ф12.7mm(1/2″) pre polarization test capacitor microphone with sound pressure sensitivity of 50mv/pa (the pressure sensitivity level is -26db and the reference is 1 V). |
3,Frequency range: 20hz-12.5khz. |
4,Frequency weight: A, C, Z. |
5,Time calculation right: F, s, i. |
6,Exchange rate: default is 3, and can be set to 4 or 5. |
7,Sound level measurement range: 35dba-130dba, 40dbc-130dbc, 45dbz-130dbz. |
8,Automatic calibration: range ± 5dB (reference sound pressure sensitivity is 50mv/pa). |
9,Measurement range of acoustic exposure: 0.001 pa2s-999 pa2s and 0.278 pa2h-999pa2h, automatic conversion unit; |
10,Measurement range of noise dose: 0.001% ~ 9999%; |
11,Measurement range of sound exposure level: 37.0dba-199.9dba, 47.0dbc-199.9dbc, 52.0dbz-199.9dbz. |
12,Normalized 8-hour measurement range: 0.0 db-130.0 DB |
13,Measurement range of standard deviation: 0.0 db-50.5 dB. |
14. Main display: 0.96 inch (128 × 64) dot matrix LCD display, showing LP, 1sleq, Leq, Lae, NDA, L5, L10, L50, L90, L95, Lmax, lmin and SD, and other parameters, and it also has overload, under quantity limit, battery voltage low drop and other indicators. |
15. Time setting: user defined time (3S ~ 99h59min59s) |
16. SD card: 8g. |
17. Data output connector: data output type-C socket, which can be connected to PC program for data analysis. |
18. Print output: Bluetooth mode, which can connect the printer provided by the company to print the measurement results. |
19 power supply: built in lithium battery, which can work continuously for more than 24 hours. |
20. Overall dimension: length × width × thickness 105mm × 52mm × 33 mm. |
21. Enclosure: flame retardant enclosure. |
22. Weight: 220g. |
23. Operating temperature range: 0 ℃ ~ +40 ℃. |
MEWOI-HY106A(Configuration 1) Main Features and Functions:
1,Performance grade: equivalent to the class 2 sound level meter conforming to gb/t 3785.1-2010 electroacoustic sound level meter part 1: specification. |
2,Microphone: Class 2 Ф12.7mm(1/2″) pre polarization test capacitor microphone with sound pressure sensitivity of 50mv/pa (the pressure sensitivity level is -26db and the reference is 1 V). |
3,Frequency range: 20hz-12.5khz. |
4,Frequency weight: A, C, Z. |
5,Time calculation right: F, s, i. |
6,Exchange rate: default is 3, and can be set to 4 or 5. |
7,Sound level measurement range: 35dba-130dba, 40dbc-130dbc, 45dbz-130dbz. |
8,Automatic calibration: range ± 5dB (reference sound pressure sensitivity is 50mv/pa). |
9,Measurement range of acoustic exposure: 0.001 pa2s-999 pa2s and 0.278 pa2h-999pa2h, automatic conversion unit; |
10,Measurement range of noise dose: 0.001% ~ 9999%; |
11,Measurement range of sound exposure level: 37.0dba-199.9dba, 47.0dbc-199.9dbc, 52.0dbz-199.9dbz. |
12,Normalized 8-hour measurement range: 0.0 db-130.0 DB |
13,Measurement range of standard deviation: 0.0 db-50.5 dB. |
14.11 built-in 1 / 1 octave filters with center frequencies of 16 Hz, 31.5 Hz, 63 Hz, 125 Hz, 250 Hz, 500 Hz, 1 kHz, 2 kHz, 4 kHz, 8 kHz and 16 kHz. |
15. Main display: 0.96 inch (128 × 64) dot matrix LCD display, showing LP, 1sleq, Leq, Lae, NDA, L5, L10, L50, L90, L95, Lmax, lmin and SD, and other parameters, and it also has overload, under quantity limit, battery voltage low drop and other indicators. |
16. Time setting: user defined time (3S ~ 99h59min59s) |
17. SD card: 8g. |
18. Data output connector: data output type-C socket, which can be connected to PC program for data analysis. |
19. Print output: Bluetooth mode, which can connect the printer provided by the company to print the measurement results. |
20. power supply: built in lithium battery, which can work continuously for more than 24 hours. |
21. Overall dimension: length × width × thickness 105mm × 52mm × 33 mm. |
22. Enclosure: flame retardant enclosure. |
23. Weight: 220g. |
24. Operating temperature range: 0 ℃ ~ +40 ℃. |
MEWOI-HY106B(Configuration 2) Main Features and Functions:
1,Performance grade: equivalent to the class 2 sound level meter conforming to gb/t 3785.1-2010 electroacoustic sound level meter part 1: specification. |
2,Microphone: Class 2 Ф12.7mm(1/2″) pre polarization test capacitor microphone with sound pressure sensitivity of 50mv/pa (the pressure sensitivity level is -26db and the reference is 1 V). |
3,Frequency range: 20hz-12.5khz. |
4,Frequency weight: A, C, Z. |
5,Time calculation right: F, s, i. |
6,Exchange rate: default is 3, and can be set to 4 or 5. |
7,Sound level measurement range: 35dba-130dba, 40dbc-130dbc, 45dbz-130dbz. |
8,Automatic calibration: range ± 5dB (reference sound pressure sensitivity is 50mv/pa). |
9,Measurement range of acoustic exposure: 0.001 pa2s-999 pa2s and 0.278 pa2h-999pa2h, automatic conversion unit; |
10,Measurement range of noise dose: 0.001% ~ 9999%; |
11,Measurement range of sound exposure level: 37.0dba-199.9dba, 47.0dbc-199.9dbc, 52.0dbz-199.9dbz. |
12,Normalized 8-hour measurement range: 0.0 db-130.0 DB |
13,Measurement range of standard deviation: 0.0 db-50.5 dB. |
14.11 Built in 28pcs 1 / 3 octave filters, center frequency: 20 Hz, 25 Hz, 31.5 Hz, 40 Hz, 50 Hz, 63 Hz, 80 Hz, 100 Hz, 125 Hz, 160 Hz, 200 Hz, 250 Hz, 315 Hz, 400 Hz, 500 Hz, 630 Hz, 800 Hz, 1 kHz, 1.25 kHz, 1.6 kHz, 2 kHz, 2.5 kHz, 3.15 kHz, 4 kHz, 5 kHz, 6.3 kHz, 8 kHz and 10 kHz. |
15. Main display: 0.96 inch (128 × 64) dot matrix LCD display, showing LP, 1sleq, Leq, Lae, NDA, L5, L10, L50, L90, L95, Lmax, lmin and SD, and other parameters, and it also has overload, under quantity limit, battery voltage low drop and other indicators. |
16. Time setting: user defined time (3S ~ 99h59min59s) |
17. SD card: 8g. |
18. Data output connector: data output type-C socket, which can be connected to PC program for data analysis. |
19. Print output: Bluetooth mode, which can connect the printer provided by the company to print the measurement results. |
20. power supply: built in lithium battery, which can work continuously for more than 24 hours. |
21. Overall dimension: length × width × thickness 105mm × 52mm × 33 mm. |
22. Enclosure: flame retardant enclosure. |
23. Weight: 220g. |
24. Operating temperature range: 0 ℃ ~ +40 ℃. |
MEWOI-HY106C(Configuration 3)Main Features and Functions:
1,Performance grade: equivalent to the class 2 sound level meter conforming to gb/t 3785.1-2010 electroacoustic sound level meter part 1: specification. |
2,Microphone: Class 2 Ф6.35mm(1/4″) pre polarization test capacitor microphone grade 2, sound pressure sensitivity is 1mV / PA (the voltage sensitivity level is - 60dB and the reference is 1V). |
3,Frequency range: 20hz-12.5khz. |
4,Frequency weight: A, C, Z. |
5,Time calculation right: F, s, i. |
6,Exchange rate: default is 3, and can be set to 4 or 5. |
7,Sound level measurement range: 60dBA-145dBA、65dBC-145dBC、75dBZ-145dBZ。 |
8,Automatic calibration: range ± 5dB (reference sound pressure sensitivity is 50mv/pa). |
9,Measurement range of acoustic exposure: 0.001 pa2s-999 pa2s and 0.278 pa2h-999pa2h, automatic conversion unit; |
10,Measurement range of noise dose: 0.001% ~ 9999%; |
11,Measurement range of sound exposure level: 67.0dBA-199.9dBA、72.0dBC-199.9dBC、77.0dBZ-199.9dBZ。 |
12,Normalized 8-hour measurement range: 0.0 db-145.0 DB |
13,Measurement range of standard deviation: 0.0 db-50.5 dB. |
14. Main display: 0.96 inch (128 × 64) dot matrix LCD display, showing LP, 1sleq, Leq, Lae, NDA, L5, L10, L50, L90, L95, Lmax, lmin and SD, and other parameters, and it also has overload, under quantity limit, battery voltage low drop and other indicators. |
15. Time setting: user defined time (3S ~ 99h59min59s) |
16. SD card: 8g. |
17. Data output connector: data output type-C socket, which can be connected to PC program for data analysis. |
18. Print output: Bluetooth mode, which can connect the printer provided by the company to print the measurement results. |
19 power supply: built in lithium battery, which can work continuously for more than 24 hours. |
20. Overall dimension: length × width × thickness 105mm × 52mm × 33 mm. |
21. Enclosure: flame retardant enclosure. |
22. Weight: 220g. |
23. Operating temperature range: 0 ℃ ~ +40 ℃. |
MEWOI-HY106D(Configuration 4) Main Features and Functions:
1,Performance grade: equivalent to the class 2 sound level meter conforming to gb/t 3785.1-2010 electroacoustic sound level meter part 1: specification. |
2,Microphone: Class 2 Ф6.35mm(1/4″) pre polarization test capacitor microphone grade 2, sound pressure sensitivity is 1mV / PA (the voltage sensitivity level is - 60dB and the reference is 1V). |
3,Frequency range: 20hz-12.5khz. |
4,Frequency weight: A, C, Z. |
5,Time calculation right: F, s, i. |
6,Exchange rate: default is 3, and can be set to 4 or 5. |
7,Sound level measurement range: 60dBA-145dBA、65dBC-145dBC、75dBZ-145dBZ。 |
8,Automatic calibration: range ± 5dB (reference sound pressure sensitivity is 50mv/pa). |
9,Measurement range of acoustic exposure: 0.001 pa2s-999 pa2s and 0.278 pa2h-999pa2h, automatic conversion unit; |
10,Measurement range of noise dose: 0.001% ~ 9999%; |
11,Measurement range of sound exposure level: 67.0dBA-199.9dBA、72.0dBC-199.9dBC、77.0dBZ-199.9dBZ。 |
12,Normalized 8-hour measurement range: 0.0 db-145.0 DB |
13,Measurement range of standard deviation: 0.0 db-50.5 dB. |
14.11 built-in 11pcs 1 / 1 octave filters with center frequencies of 16 Hz, 31.5 Hz, 63 Hz, 125 Hz, 250 Hz, 500 Hz, 1 kHz, 2 kHz, 4 kHz, 8 kHz and 16 kHz. |
15. Main display: 0.96 inch (128 × 64) dot matrix LCD display, showing LP, 1sleq, Leq, Lae, NDA, L5, L10, L50, L90, L95, Lmax, lmin and SD, and other parameters, and it also has overload, under quantity limit, battery voltage low drop and other indicators. |
16. Time setting: user defined time (3S ~ 99h59min59s) |
17. SD card: 8g. |
18. Data output connector: data output type-C socket, which can be connected to PC program for data analysis. |
19. Print output: Bluetooth mode, which can connect the printer provided by the company to print the measurement results. |
20. power supply: built in lithium battery, which can work continuously for more than 24 hours. |
21. Overall dimension: length × width × thickness 105mm × 52mm × 33 mm. |
22. Enclosure: flame retardant enclosure. |
23. Weight: 220g. |
24. Operating temperature range: 0 ℃ ~ +40 ℃. |
MEWOI-HY106E(Configuration 5) Main Features and Functions:
1,Performance grade: equivalent to the class 2 sound level meter conforming to gb/t 3785.1-2010 electroacoustic sound level meter part 1: specification. |
2,Microphone: Class 2 Ф6.35mm(1/4″) pre polarization test capacitor microphone grade 2, sound pressure sensitivity is 1mV / PA (the voltage sensitivity level is - 60dB and the reference is 1V). |
3,Frequency range: 20hz-12.5khz. |
4,Frequency weight: A, C, Z. |
5,Time calculation right: F, s, i. |
6,Exchange rate: default is 3, and can be set to 4 or 5. |
7,Sound level measurement range: 60dBA-145dBA、65dBC-145dBC、75dBZ-145dBZ。 |
8,Automatic calibration: range ± 5dB (reference sound pressure sensitivity is 50mv/pa). |
9,Measurement range of acoustic exposure: 0.001 pa2s-999 pa2s and 0.278 pa2h-999pa2h, automatic conversion unit; |
10,Measurement range of noise dose: 0.001% ~ 9999%; |
11,Measurement range of sound exposure level: 67.0dBA-199.9dBA、72.0dBC-199.9dBC、77.0dBZ-199.9dBZ。 |
12,Normalized 8-hour measurement range: 0.0 db-145.0 DB |
13,Measurement range of standard deviation: 0.0 db-50.5 dB. |
14.11 Built in 28pcs 1 / 3 octave filters, center frequency: 20 Hz, 25 Hz, 31.5 Hz, 40 Hz, 50 Hz, 63 Hz, 80 Hz, 100 Hz, 125 Hz, 160 Hz, 200 Hz, 250 Hz, 315 Hz, 400 Hz, 500 Hz, 630 Hz, 800 Hz, 1 kHz, 1.25 kHz, 1.6 kHz, 2 kHz, 2.5 kHz, 3.15 kHz, 4 kHz, 5 kHz, 6.3 kHz, 8 kHz and 10 kHz. |
15. Main display: 0.96 inch (128 × 64) dot matrix LCD display, showing LP, 1sleq, Leq, Lae, NDA, L5, L10, L50, L90, L95, Lmax, lmin and SD, and other parameters, and it also has overload, under quantity limit, battery voltage low drop and other indicators. |
16. Time setting: user defined time (3S ~ 99h59min59s) |
17. SD card: 8g. |
18. Data output connector: data output type-C socket, which can be connected to PC program for data analysis. |
19. Print output: Bluetooth mode, which can connect the printer provided by the company to print the measurement results. |
20. power supply: built in lithium battery, which can work continuously for more than 24 hours. |
21. Overall dimension: length × width × thickness 105mm × 52mm × 33 mm. |
22. Enclosure: flame retardant enclosure. |
23. Weight: 220g. |
24. Operating temperature range: 0 ℃ ~ +40 ℃. |