MEWOI117BE AC/DC Clamp Leakage Current Sensor is designed for measuring AC/DC current and leakage current under 600V line voltage, by adopting the latest CT technology and digital integrate technology. The small clamp is suitable for line densely places (electric power measurement system, the high speed rail system, car circuit overhaul, and so on), non-contact measurement, to ensure safe operation. It is small, with high precision, stable performance, can be connected with phase detection analyzer, industrial control equipment, data recorder, oscilloscope, electric power quality analyzer, high precision multi-meter. The sensor is widely applied in those fields as electricity, communications, meteorology, railroad, car industry, oilfield, construction, measurement, scientific & research teaching institutes, industrial and mining establishments.

Ⅱ.TECHNICAL SPECIFICATION

 Function

Measurement of AC/DC current, leakage current

Power Supply

Zn-Mn dry battery, 6RL61, 9V. Continually using for 100 hours, connecting external power supply is also available for long time using.

Test Mode

Clip-on CT, non-contact measurement

Clamp Size

16*18mm

Input Range

0mA-60.0A AC/DC

Output Voltage

10mV/A;100mV/A(corresponding)

Output Range

1V peak max

Resolution

1mA AC/DC

Accuracy

±3%FS(23°C±5°C, below 5%rh)

Phase Error

≤3°(AC 50Hz/60Hz; 23°C±2°C)

Calibration

Adjust ZERO to calibrate, eliminate external electric field interference

Output Wire

Core wire: signal positive output; shielding wire: signal ground

Lead length

2m

Dimension

LWH: 168mm×65mm×34mm

Frequency

AC: 45Hz-400Hz

DC: DC-100kHz

Test Position

Tested wire in the jaw center

Line Voltage

AC600V

Weight

170g (Including the battery)

Working Current

5mA

Working Temperature and Humidity

-10°C-50°C,below 80%rh

Limit Temperature Error

-10°C-0°C and 40°C-50°C, within 2%rdg

Storage Temperature and Humidity

-10°C-60°C,below 70%rh

Insulating Strength

AC3700V/rms (between the alloy of the clamp and the housing)

Applicable safety rules

IEC1010-1, IEC1010-2-032, Pollution level 2, CAT Ⅲ(600V)

Accessories

Sensor: 1piece; Battery(6F22,9V): 1piece; User Manual/Warranty card/ Certification: 1 copy

Ⅱ.TECHNICAL SPECIFICATION

 Function

Measurement of AC/DC current, leakage current

Power Supply

Zn-Mn dry battery, 6RL61, 9V. Continually using for 100 hours, connecting external power supply is also available for long time using.

Test Mode

Clip-on CT, non-contact measurement

Clamp Size

16*18mm

Input Range

0mA-60.0A AC/DC

Output Voltage

10mV/A;100mV/A(corresponding)

Output Range

1V peak max

Resolution

1mA AC/DC

Accuracy

±3%FS(23°C±5°C, below 5%rh)

Phase Error

≤3°(AC 50Hz/60Hz; 23°C±2°C)

Calibration

Adjust ZERO to calibrate, eliminate external electric field interference

Output Wire

Core wire: signal positive output; shielding wire: signal ground

Lead length

2m

Dimension

LWH: 168mm×65mm×34mm

Frequency

AC: 45Hz-400Hz

DC: DC-100kHz

Test Position

Tested wire in the jaw center

Line Voltage

AC600V

Weight

170g (Including the battery)

Working Current

5mA

Working Temperature and Humidity

-10°C-50°C,below 80%rh

Limit Temperature Error

-10°C-0°C and 40°C-50°C, within 2%rdg

Storage Temperature and Humidity

-10°C-60°C,below 70%rh

Insulating Strength

AC3700V/rms (between the alloy of the clamp and the housing)

Applicable safety rules

IEC1010-1, IEC1010-2-032, Pollution level 2, CAT Ⅲ(600V)

Accessories

Sensor: 1piece; Battery(6F22,9V): 1piece; User Manual/Warranty card/ Certification: 1 copy