Contact Us for Quotation | Email:mewoi@mewoi.com | Whatsapp: +8618620373879 |
Basic Functions
Basic Function | Range | Basic Accuracy | ||
201 | 202 | 203 | ||
DC Voltage | 200mV/2V/20V/200V | ±(0.5%+2) | ±(0.5%+2) | ±(0.5%+2) |
500V | ±(0.8%+2) | ±(0.8%+2) | ±(0.8%+2) | |
AC Voltage | 200V/500V | ±(1.2%+10) | ±(1.2%+10) | ±(1.2%+10) |
DC Current | 200uA | ±(1.0%+2) | ||
2mA/20mA | ±(1.0%+2) | ±(1.0%+2) | ||
200mA | ±(1.2%+2) | ±(1.2%+2) | ±(1.2%+2) | |
10A | ±(2.0%+5) | ±(2.0%+5) | ±(2.0%+5) | |
Resistance | 200Ω | ±(0.8%+5) | ±(0.8%+5) | ±(0.8%+5) |
2kΩ/20kΩ/200kΩ | ±(0.8%+2) | ±(0.8%+2) | ±(0.8%+2) | |
20MΩ | ±(1.0%+5) | ±(1.0%+5) | ±(1.0%+5) | |
200MΩ | ± [ 5.0%(reading -10)+20] |
Celsius | (-20 ~ 1000) ℃ | ±(1.0%+3) | ||
Fahrenheit | (-4~1832) ℉ | ±(1.0%+4) | ||
Special Function | ||||
Diode test | √ | √ | √ | |
Backlight | √ | √ | √ | |
Data Hold | √ | √ | √ | |
Continuity | √ | √ | ||
200mA protection | √ | √ | √ | |
Square wave output | √ | |||
Celsius & Fahrenheit | √ | |||
Battery measurement | √ |
SELECTION GUIDE
Model No. | Name | DC Voltage | AC Voltage | DC Current | AC Current | Resistance | Capacitance | Frequency | Temperature | Inductance |
Multimeter | 200mV/2V/20V /200V/500V | 200V/500V | 200uA/200m A/10A | — | 200Ω/2kΩ/20kΩ/200kΩ/20MΩ | — | — | — | — | |
Multimeter | 200mV/2V/20 V/200V/500V | 200V/500V | 2mA/20m A/200mA/10A | — | 200Ω/2kΩ/20kΩ/200kΩ/20MΩ/200MΩ | — | — | — | — | |
Multimeter | 200mV/2V/20 V/200V/500V | 200V/500V | 2mA/20m A/200mA/10A | — | 200Ω/2kΩ/20kΩ/200kΩ/20MΩ | — | — | (-20 ~ 1000) ℃,(-4~1832) ℉ | — | |
Multimeter | 200mV/2V/20 V/200V/600V | 2V/200V/600V | 20mA/200m A/10A | 200mA/10A | 200Ω/2kΩ/20kΩ/200kΩ/20MΩ | 20nF/200nF/2uF /20uF/200uF/2000uF | 10Hz/100Hz/1KHz/10KHz/100KHz/2MHz | — | — | |
Capacitance Meter | — | — | — | — | — | 200pF/2nF/20nF/200n F/2uF/20uF/200uF /2000uF/20000uF | (200pF/2nF/20nF/200nF/2uF,800Hz),(20uF,80Hz),(200uF/2000uF/20000uF,8Hz) | — | — | |
Multimeter | 200mV/2V/20 V/200V/1000V | 200mV/2V/20V /200V/750V | 200uA/2mA/20mA /200mA/20A | 20mA/200mA/20A | 200Ω/2kΩ/20kΩ/200kΩ/20MΩ | 2nF/20nF/200nF/2u F/20uF/200uF /2000uF/20mF | — | (-20~1000)℃ | — | |
Multimeter | 400mV/4V/40 V/400V/1000V | 4V/40/400V /750V | 400uA/4000uA/40mA /400mA/10A | 400uA/4000uA/40mA/400mA/10A | 400Ω/4kΩ/40kΩ/400kΩ/4MΩ/40MΩ | 10nF/100nF/1uF/10u F/100uF/1mF/10mF/100mF | 100/1000/10k/100k/1M/30MHz | (-20~1000)℃ (-4-1832)℉ | — | |
Multimeter | 600mV/6V/60 V/600V/1000V | 6V/60V/600V /750V | 60mA/600mA/6A /10A | 60mA/600mA/6A/10A | 600Ω/6kΩ/60kΩ/600kΩ/6MΩ/60MΩ | 40nF/400nF/4u F/40uF/200uF | 100Hz/1000Hz/10kHz/100kHz/1MHz/20MHz | (-20~1000) ℃,(0~1832) ℉ | — | |
Multimeter | 200mV/2V/20V /200V/1000V | 200mV/2V/20V /200V/750V | 2mA/20mA/200mA /20A | 2mA/20mA/200mA /20A | 200Ω/2kΩ/20kΩ/200k Ω/2MΩ/200MΩ/2000MΩ | 20nF/200nF/2uF /20uF/200uF | 2kHz/20kHz /200kHz/2000kHz/10MHz | (-20 ~ 1000)℃ | 2mH/20m H/200mH/2H/20H | |
MEWOI86D | With USB Multimeter | 600mV/6V/60V /600V/1000V | 6V/60V/600V /750V | 600uA/6000uA /60mA/600mA /6A/10A | 600uA/6000uA /60mA/600mA/6A/10A | 600Ω/6kΩ/60kΩ/600k Ω/6MΩ/60MΩ | 40nF/400nF/4uF /40uF/200uF | 100Hz/1kHz/10kHz/100kHz/1MHz/30MHz | (-20 ~ 1000) ℃ /(0~1832) ℉ | — |
MEWOI81D | Multimeter | 400mV/4V/40V/400V/600V | 4V/40V/400V/600V | 400uA/4000uA/40mA/400mA/10A | 400uA/4000uA/40mA/400mA/10A | 400Ω/4kΩ/40kΩ/400kΩ/4MΩ/40MΩ | 4nF/40nF/400nF/4u F/40uF/100uF/1000uF | 1Hz/10Hz/100Hz/1kHz/10kHz/100kHz/30MHz | (-20-1000)℃ (-4~1832)℉ | — |
MEWOI81B | Multimeter | 200mV/2V/20V/200V/600V | 200mV/2V/20V/200V/600V | 200uA/2000uA/20mA/200mA/10A | 200uA/2000uA/20mA/200mA/10A | 200Ω/2kΩ/20kΩ/200kΩ/2MΩ/20MΩ | — | — | (-20-1000)℃,(0-1832)℉ |