Contact Us for Quotation | Email1:billy.sz.china@gmail.com | Whatsapp: +8618620373879 |
Click to: Products Map | Email2: mewoi@mewoi.com |
TECHNICAL SPECIFICATION
Power | 4*1.5V AA Batteries |
AC Current(A) | 40/100/400/1000A±2% |
AC Voltage(V) | 100/300/600V±1.2% |
ActivePower Range(KW) | 4/10/40/100/600KW±3% |
Apparent Power(KWA) | 4/10/40/100/600KW±3% |
Reactive Power(KW) | 4/10/40/100/600KW±4% |
Power Factor | 0.3-1.0(Capacitive or inductive) |
Power Energy Range | 10/100/1000/10000KWh±3% |
Frequency | 20-1000Hz±0.5% |
Display | 4digits max9999 |
Measured Wire Position | Measured wire at approximately the geometric center of the clamp |
Data Storage | 28 sets |
RS232 Interface | With RS232 interface, download data to computer for analysis and management |
Communication Wire | RS232 communication wire |
Meter Size | 300mm×103mm×51mm |
Backlight | YES |
Data Hold | "HOLD" symbol appears |
Overflow | "OL" symbol appears |
Automatic Shutdown | NO |
Voltage Detection | Low battery display |
Weight | 640g |
Working Temperature and Humidity | -10℃-40℃; 80%rh |
Storage Temperature and Humidity | -10℃-60℃; below 70%rh |
SafetySpecifications | CAT Ⅲ(600V) |
Accessories | 1, Test Leads, 2, Alligator clip,3, RS232C interface cable ,4, PC Data Record graph software 5, Carry Case 6, Batteries and User's manual |
SELECTION GUIDE 1
Large Caliber Three Phase Leakage Current AMP/VOLT Clamp On Power Tester
(Click "Blue" Marked Model No. To View The Spec)
Model No. | Range | Resolution | Power Range | Frequency Range | Clamp Size | RS232 Interface | Data Stroge |
MEWOI8300 | 0.00mA -1200A, 0.00V- 600V, | 0.01mA | AC 0.5W-720KW | 25Hz-100Hz | 80*80mm | √ | 200sets |
MEWOI8300B | 0.0A -2000A, 0.00V-600V, | 0.1A | AC 0.5W-1200KW | 25Hz-100Hz | 80*80mm | √ | 200sets |
SELECTION GUIDE 2
Large Caliber Leakage Clamp Meter
Click "Blue"marked Model No. to View the Spec
Model | Range | Resolution | Clamp Size | LCD Display | Data Storage | RS232 |
MEWOI8000 | AC 0.00mA~1200A, 0~600V | 0.01mA,0.01V | 80*80mm | √ | 99 sets | √ |
MEWOI8000B | AC 0.00mA~2000A, 0~600V | 0.01mA, 0.01V | 80*80mm | √ | 99 sets | √ |
MEWOI8000C | AC 0.0A~2500A,0~600V | 0.0A, 0.01V | 80*80mm | √ | 99 sets | √ |
MEWOI8100 | AC 0.0mA~3200A, 0.00~600V | 0.1mA, 0.01V | 108*148mm | √ | 99 sets | √ |
MEWOI8100B | AC 0.0A~4000A, 0.00~600V | 0.1A, 0.01V | 108*148mm | √ | 99 sets | √ |
MEWOI8100E | DC0.0A~2000A, AC 0.0A~1000A, 0.00~600V | 0.1A, 0.01V | 108*148mm | √ | 99 sets | √ |
TECHNICAL SPECIFICATION
Function | Measure three phase AC voltage, leakage current, current, active power, reactive power, apparent power, power, phase between current and voltage, phase between phase voltage, frequency, power energy, phase sequence |
Power | 6V DC(LR6×4 alkaline dry batteries, continuously working for 12 hours) |
Test Mode | Clamp CT, integral mode |
Clamp Size | 80mm×80mm(can clamp electric cable of 80mm diameter, or 96mm×4mm flat cable and steel earth wires) |
Current Range | AC 0.00mA-1200A, Resolution: 0.01mA |
Power Range | AC 0.5W-720KW, Resolution: 0.01W |
Voltage Range | AC 0-600V, Resolution: 0.01V |
Frequency Range | 25Hz-100Hz, Resolution: 0.1Hz |
Phase Range | 0.0°-360.0°, Resolution: 0.1° |
Power Factor Range | 0.3-1.0(Capacitive or inductive) , Resolution: 0.001 |
Power Energy Range | 0.0000KWh-72000KWh, Resolution: 0.0001KWh |
Measured Wire Position | Measured wire at approximately the geometric center of the clamp |
Data Storage | 200 sets, “FULL the memory is full ” symbol indicate |
RS232 Interface | With RS232 interface, download data to computer for analysis and management |
Communication Wire | RS232 communication wire, 1.8m |
Frequency | 50Hz ,60Hz automatic identification |
Gear Shift | Automatic shift |
Sample Rate | About 2 times/second |
Line Voltage | Below AC 600V line measurement |
Display Mode | LCD: 128dots×64dots; Display area: 43mm×29mm |
Meter Size | Length 275mm × Width 145mm × Height 40mm |
Backlight | Controlled by “ *" key |
Data Hold | "HOLD" symbol appears |
Overflow | "OL" symbol appears |
Automatic Shutdown | Automatically shutdown about 15 minutes after power on to reduce battery consumption |
Voltage Detection | Low battery symbol appears to remind the replacement of battery when the battery voltage drops below 5.2V. |
Weight | 1kg(with batteries and accessories) |
Working Current | 50mA with enabled backlight; 25mA with disabled backlight |
Working Temperature and Humidity | -10℃-40℃; 80%rh |
Storage Temperature and Humidity | -10℃-60℃; below 70%rh |
Insulation strength | AC 3700V/rms(between core and shell) |
SafetySpecifications | IEC1010-1, IEC1010-2-032, 2 class of pollution, CAT Ⅲ(600V) |
Accessories | Meter: 1 PC; Test Wires: 4 PCS (Yellow, Green, Red, Black), RS232 Data Wires: 1PC; Disk: 1 PC; Battery(LR6): 4PCS; Meter Box: 1 PC |
Meter: 1 PC; Test Wires: 4 PCS (Yellow, Green, Red, Black), RS232 Data Wires: 1PC; Disk: 1 PC; Battery(LR6): 4PCS; Meter Box: 1 PC