MEWOI-YH128A TTR Tester,3-phase transformer turn ratio tester,transformer turn ratio finder,MEDIDOR DE RELAÇÃO DE TRANSFORMAÇÃO

OEM/ODM Testing Instruments Manufacturer

Contact Us for QuotationEmail:mewoi@mewoi.comWhatsapp: +8618620373879

MEWOI-YH128A 3-phase transformer turn ratio tester,TTR Tester,transformer turn ratio finder,MEDIDOR DE RELAÇÃO DE TRANSFORMAÇÃO,Medidor de Relação em Espiras

INTRODUCTION

During the production process of semi-finished products and finished products of power transformers, before the newly installed transformers are put in o operation and in accordance with the preventive test procedures of the National Electric Power Ministry, it is required that the transformers in operation be regularly tested for the turns ratio or voltage ratio. The traditional variable bridge operation is cumbersome, the reading is not intuitive, and the necessary conversion is performed. The test result is only a phase change ratio. The automatic ratio change tester overcomes the shortcomings of the traditional turn ratio test. The instrument completes the three-phase ratio test at a time, and the test speed is fast and the accuracy is high.

MAIN FEATURES

1,The test range is wide, up to 5000.

2, Test speed is fast, 7 seconds to complete the three-phase test

3,Z-connected transformer test.

4,The clock and date display even power is off, data storage.

5,High and low voltage reverse connection protection function.

6,Transformer short circuit, inter-turn short circuit protection.

7,Thermal printer output function, fast, silent.

8,Equipped with RS232, USB interface, easy to connect to the computer to export data.

9,Small size and light weight.

TECHNICAL SPECIFICATION

Measure Range

0.9~5000

Accuracy

 

0.1%±2 words (below 500);

0.2%±2 words (500~2000);

0.5%±2 words (2000 or more);

Resolution

Minimum 0.0001.

Output voltage

160v/10v (automatic selection).

Working power

AC220v ± 10%, 50hz.

Working Temperature

–20°C ~ 40°C.

Relative Humidity

≤85%, no condensation

Accessories

Host:1set,High Voltage end test cables, Low voltage end test cables, Self-checking wires, Power Cord, Printing Paper, User Manual

SELECTION GUIDE

Model No.RangeAccuracyResolutionOutput voltageWorking PowerRS232/USBPrinter

MEWOI-UCT-B-TCT-A.80.jpg

MEWOI-UCT-B  

0.9~100000.1%±2dgt(below 500);

0.2%±2dgt(500~2000);

0.3%±2dgt(2000~4000);

0.5% ± 2dgt(4000 or more).

Minimum 0.0001.160v/10v (automatic selection).AC220v ± 10%, 50hz.-

MEWOI-UCT-C-TCT-B.80.jpg

MEWOI-UCT-C

0.9~100000.1%±2dgt(below 500);

0.2%±2dgt(500~2000);

0.3%±2dgt(2000~4000);

0.5% ± 2dgt(4000 or more).

Minimum 0.0001.160v/10v (automatic selection).

AC220v ± 10%, 50hz

Built-in battery

-

MEWOI-128A Transformer Turn Ratio Tester_80.jpg

MEWOI-YH128A

0.9~50000.1%±2dgt(below 500);

0.2%±dgt(500~2000);

0.5%±2dgt(2000~5000);

Minimum 0.0001.160v/10v (automatic selection).AC220v ± 10%, 50hz.

MEWOI-YH128B.80.jpg

MEWOI-YH128B

0.9~100000.1%±2dgt(below 500);

0.2%±2dgt(500~2000);

0.5%±2dgt(2000~10000);

Minimum 0.0001.160v/10v (automatic selection).AC220v ± 10%, 50hz.


Telephone
Product Center
Aftersales
QQ