Contact Us for Quotation | Email:mewoi@mewoi.com | Whatsapp: +8618620373879 |
Ⅰ.INTRODUCTION
Click to download: Selection Map
MEWOI168BE Clamp on AC/DC current Sensor is designed for testing AC/DC current with voltage under 600V on-line. Adopt the latest CT technology and digital integrated technology. There is not any metallic conductor outside the clamps, non-contact test to ensure save. It is small in size; high accuracy can connect with multi-meter, oscilloscope, electric power quality analyzer, etc. Widely applied in electricity, communication, meteorology, railway, oilfield, construction, measurement, scientific and research teaching unit, industrial and mining enterprises. |
TECHNICAL SPECIFICATION
Function | Measurement of AC current, phase, power energy, power, power factor |
Power supply | Zn-Mn dry battery 6F22 9VDC(external power is allowed) |
Rated current | 15mA |
Test mode | Clamp CT, noncontact measurement |
Clamp Size | Φ68mm |
Range | DC 0.0~2000A; AC 0.0~1000A |
Resolution | 0.1A AC/DC |
Signal output | 1mV/1A |
Accuracy | ±2.0%FS(50Hz/60Hz; 23℃±2℃, below 70%RH, keep the wire be in the center of clamp) |
Phase Error | ≤3°(AC50Hz/60Hz; 23℃±2℃) |
Zero clearing | Press ZERO key can clear the data, eliminate the effect of geomagnetic field to the measure of AC current |
Output connection | Standard connection: Red wire-positive output; Yellow wire-negative output. |
Output Wire Length | 2m |
Measured Wire Position | Approximately in the geometric center of the clamp, the errors for deviating the center of the clamp increase 1.5%rdg. |
Frequency | AC 45Hz~400Hz |
Voltage of circuit | Circuit with the voltage below AC 600V |
Voltage of battery | When the voltage of battery is below 7.2V, the LED will be lighted when the voltage is low, indicate to replace the battery. |
Dimension | 224mm×115mm×43mm |
Weight | 515g |
Working Environment | -15℃~45℃;80%rh below |
Storage Environment | -10℃~60℃;70%rh below |
Insulation Strength | AC 3700V/rms. (between core and shell) |
Safety Rules | IEC1010-1,IEC1010-2-032,Pollution degree 2,CAT Ⅲ(600V) |
Accessory | Sensor:1pc; battery(6F22 9V):1pc |
SELECTION GUIDE 1
Clamp on Current Sensor Probe For Terminals Such Mulitimeter&Oscilloscope
Click "Blue" marked Model No. to View the Spec
Model | Range | Resolution | Clamp Size | Power Supply&output | Hall effect | Current induction output,Direct Coil tap | Others |
MEWOI107BE | 0mA~60A (AC/DC) | 1mA | Φ7mm | Power Supply: 9VDC, Output:10mV/A,100mV/A, Accuracy 3% | √ | Suitable for small spaces AC / DC leakage current, low current test. | |
MEWOI108 | 0.0mA~30A (AC) | 0.1mA, Accuracy 0.5% | Φ8 mm | √ | Suitable for small spaces AC leakage current, harmonic, phase, Power test | ||
MEWOI130 | 0.000mA~60A (AC), | 0.001mA,Accuracy: 1% | 25*30mm | √ | Double shielding, anti-jamming capability,suitable for leakage current,small current test. | ||
MEWOI130E | 0.00A~10A (DC), | 0.01A | 25*30mm | Power supply: 9VDC, output:0~2.5mV/10mA,Accuracy: 3%,Turns ratio:1:800 | Double shielding, anti-jamming capability,suitable for small DC current test. | ||
MEWOI130E2 | 0.0mA ~100mA (DC), | 0.1mA | 25*30mm | Power supply: 9VDC, output:0~2.5mV/1mA,Accuracy: 3%,Turns ratio:1:800 | Double shielding, anti-jamming capability,suitable for DC leakage current test. | ||
MEWOI130BE | 0mA~60A (AC/DC) | 1mA | 25*30mm | Power supply: 9VDC, output:10mV/A,100mV/A,Accuracy: 2% | √ | suitable for AC/DC current test | |
MEWOI135BE | 0.0A~1000A (AC/DC) | 0.1A | 30*35mm | Power supply: 9VDC, output:1mV/1A,Accuracy: 2% | √ | suitable for AC/DC current test | |
MEWOI140 | 0.00mA ~300A (AC) Turn Ratio 1:2400 | 0.01mA,Accuracy: 1% | 35*40mm | √ | Single shielding, suitable for leakage current, small current test | ||
MEWOI140B | 0.0A~600A (AC) Turn Ratio 1:4000 | 0.1A, Accuracy: 1% | 35*40mm | √ | suitable for big current test | ||
MEWOI140C | 0.0mA ~100A (AC) Turn Ratio 1:2000 | 0.1mA, Accuracy: 1% | 35*40mm | √ | suitable for current, harmonic, phase, Power test | ||
MEWOI168 | 0.00mA ~1000A (AC) | 0.01mA, Accuracy: 1% | Φ68mm | √ | Double shielding, anti-jamming capability,suitable for leakage current, current test | ||
MEWOI168B | 0.0A~2000A (AC) | 0.1A, Accuracy: 2% | Φ68mm | √ | suitable for current, harmonic, phase, Power test | ||
MEWOI168C | 0.00A~1000A (AC) | 1mA, Accuracy: 2% | Φ68mm | √ | suitable for current, harmonic, phase, Power test | ||
MEWOI168BE | 0.0A~2000A (DC), 0.0A~1000A(AC) | 0.1mA | Φ68mm | Power supply: 9VDC, output:1mV/1A, Accuracy: 2% | √ | suitable for AC/DC big current test |
SELECTION GUIDE 2
Flexible Coil Current Sensor Probe For Terminals Such as Mulitimeter&Oscilloscope
Click "Blue" marked Model No. to View the Spec
Model | Flexible CT | Range | Resolution | Coil length | Diameter | Application |
MEWOI200G | Φ100 mm | AC 10mA~10000A~more | 10mA | 315mm (Can be customized) | φ7.5mm(suitable for narrow and cable-intensive places) | Measure AC big current, high harmonic currents, complex Waveforms current, inrush transient current. Suitable for measuring the size of a large or irregularly shaped conductor current |
MEWOI300G | Φ200 mm | AC 10mA~10000A~more | 10mA | 630mm (Can be customized) | φ7.5mm(suitable for narrow and cable-intensive places) | |
MEWOI400G | Φ300 mm | AC 10mA~10000A~more | 10mA | 1000mm (Can be customized) | φ7.5mm(suitable for narrow and cable-intensive places) |
TECHNICAL SPECIFICATION
Function | Measurement of AC current, phase, power energy, power, power factor |
Power supply | Zn-Mn dry battery 6F22 9VDC(external power is allowed) |
Rated current | 15mA |
Test mode | Clamp CT, noncontact measurement |
Clamp Size | Φ68mm |
Range | DC 0.0~2000A; AC 0.0~1000A |
Resolution | 0.1A AC/DC |
Signal output | 1mV/1A |
Accuracy | ±2.0%FS(50Hz/60Hz; 23℃±2℃, below 70%RH, keep the wire be in the center of clamp) |
Phase Error | ≤3°(AC50Hz/60Hz; 23℃±2℃) |
Zero clearing | Press ZERO key can clear the data, eliminate the effect of geomagnetic field to the measure of AC current |
Output connection | Standard connection: Red wire-positive output; Yellow wire-negative output. |
Output Wire Length | 2m |
Measured Wire Position | Approximately in the geometric center of the clamp, the errors for deviating the center of the clamp increase 1.5%rdg. |
Frequency | AC 45Hz~400Hz |
Voltage of circuit | Circuit with the voltage below AC 600V |
Voltage of battery | When the voltage of battery is below 7.2V, the LED will be lighted when the voltage is low, indicate to replace the battery. |
Dimension | 224mm×115mm×43mm |
Weight | 515g |
Working Environment | -15℃~45℃;80%rh below |
Storage Environment | -10℃~60℃;70%rh below |
Insulation Strength | AC 3700V/rms. (between core and shell) |
Safety Rules | IEC1010-1,IEC1010-2-032,Pollution degree 2,CAT Ⅲ(600V) |
Accessory | Sensor:1pc; battery(6F22 9V):1pc |
Sensor:1pc; battery(6F22 9V):1pc