Function  | Earth ground resistance measurement, voltage to ground measurement, low value resistance measurement  | 
Power Supply  | DC 9V(Zi-Mn dry battery R14S 1.5V 6 PCS, continuous standby for 300 hours )  | 
Backlight  | Controllable blue backlight, suitable for use in dark place.   | 
Measuring Mode  | Precise 3-pole measurement, simple 2-pole measurement  | 
Measuring Method  | Earth ground resistance: rated current change-pole method, measurement current 3mA Max,820Hz; Voltage to ground: average value rectification  | 
Data Mode  | Average value, maximum, minimum  | 
Wire Resistance Verification  | Avoid error caused by testing wire that is failed to be fully inserted in	o tester interface or by poor contact or by users’ replacing or lengthening testing wires, making it more accurate for earth ground resistance measurement.  | 
Display Mode  | 4-digital super-large LCD display, blue screen backlight  | 
Measuring indicator  | During measurement, LED flash indicator, LCD count down display  | 
LCD Dimension  | 128mm×75mm;Display field:124mm×67mm  | 
Dimension  | L×W×H: 215mm×190mm×95mm  | 
Testing Wires  | Three wires: each for Red 20m, Yellow 10m, and Green 5m  | 
Simple Testing Wire  | 2 wires: each for Red 1.6m and Green 1.6m  | 
Auxiliary grounding rod  | 2 PCS:Φ10mm×150mm  | 
Measuring Rate  | Voltage to ground: about 3 times/second; earth ground resistance: about 5 seconds/time  | 
Measuring Times  | Over 5000 times (Measuring 10Ω for one time on 20Ω range and take a pause for 25s)  | 
Circuit Voltage  | Measuring voltage to ground: measuring below AC 600V  | 
RS232 Interface  | Possess RS232 interface, software supervision, storage data can be uploaded to computer, saved or printed.  | 
Communication Wire  | One piece of RS232 communication wire, with length 1.5m  | 
Data Storage  | 400 sets, flash display “FULL” icon to indicate storage is full  | 
Data Hold  | Data hold function: “HOLD” icon display  | 
Data Read  | Data read function: “READ” icon display  | 
Overflow Display  | Exceeding measuring range overflow function: “OL” icon display  | 
Alarm Function  | When measuring value exceeds alarm setting value, there is “Toot-toot-toot” alarm hint  | 
Battery Voltage  | When battery voltage decreases to about 7.8V, battery voltage low icon will display, reminding to replace battery.    | 
Power Consumption  | Backlight:25mA Max  | 
Standby: 25mA Max(Backlight shut off)  | 
Measurement:70mA Max(Backlight shut off)  | 
Weight  | Tester:1443g(including battery)  | 
WorkingTemperature & Humidity  | -10℃~40℃;below 80%rh  | 
Storage temperature & humidity  | -20℃~60℃;below 70%rh  | 
Overload Protection  | Measuring earth ground resistance: between each interfaces of E-P,E-C, AC 280V/3 seconds  | 
Insulation Resistance  | Over 10MΩ(between circuit and enclosure it is 500V)  | 
Withstanding Voltage  | AC 3700V/rms (Between circuit and enclosure)  | 
Electromagnetic Features  | Wireless frequency electromagnetic field  | 
Protection Type  | IEC61010-1,IEC1010-2-31,IEC61557-1,5,IEC60529(IP54),Pollution etc. 2,CAT Ⅲ 300V  | 
Accessories  | Tester:1 pc; Ground rod:2 pcs; Testing wire: 3 pcs ;Simple testing wire: 2 pcs; RS232 line:1 pc; Software disk: 1 pc; Tester bag:1 pc  |