MEWOI7000-0mA~60.0A AC/DC High Accuracy Clamp Leaker /Current Leakage Tester

Electricity Testing Instruments manufacturer, Support OEM/ODM, your testing specialist

  • Main Features:: 1.Able to measure DC leakage current, AC leakage current 2.Small clamp, suit for densely place 3.Current range: DC/AC 0mA~60A 4.Current resolution: 1mA 5.Size of clamp:Φ7mm 6.With RS232 interface 7.Data storage: 99 sets
  • Model No.:: MEWOI7000
  • Name:: MEWOI7000-0mA~60.0A AC/DC High Accuracy Clamp Leaker /Current Leakage Tester

MEWOI OEM/ODM  Instruments Manufacturer

MEWOI OEM/ODM  Instruments ManufacturerMEWOI OEM/ODM  Instruments ManufacturerMEWOI OEM/ODM  Instruments ManufacturerMEWOI OEM/ODM  Instruments Manufacturer

Ⅰ.INTRODUCTION

Click to download:  MEWOI7000 Color Page

Click to download: Selection Map

MEWOI7000 AC/DC Clamp Leaker is specially designed for measurement of AC/DC current; by adopting up-to-date CT technology and digital integration technology. The small clamp is suitable for line densely places (electric power measurement system, the high speed rail system, car circuit overhaul, and so on), non-contact measurement, to ensure safe operation. It is a product with relatively small size, high accuracy and perfect function compared with similar leakers in the world. The leaker could be widely applied in those fields as electricity, communications, meteorology, railroad, oilfield, construction, measurement, scientific & research teaching institutes, industrial and mining establishments. it is an essential tool for electrician safety testing.

MEWOI7000 AC/DC Clamp Leaker also named: DC Leakage Current Clamp Meter, Car DC Leakage Current Clamp Meter, AC/DC Clamp Leakage Current Tester. It has those functions as data holding and data storage. It obtains one RS232 interface, communication cable and software, through which historical data inquiry is available, for data reading, exporting and printing.

Ⅱ.SELECTION GUIDE 1

High Accuracy leakage current Clamp Meter/Tester

Click "Blue" marked MODEL NO.to view the spec

ModelRange
ResolutionClamp Size
Data StorgeRS232
MEWOI7000MEWOI7000-1_.jpgAC/DC  0mA~60.0A1mAφ7mm99sets

MEWOI7000C

MEWOI7000C.80.jpg

AC/DC  0mA~60.0A1mA16mm×18mm99sets

MEWOI7100MEWOI7300-1_副本.jpg

AC/DC  0.0A~1000A0.1A30mm×35mm99sets

MEWOI7200MEWOI7300-1_副本.jpg

AC/DC  0mA~60A1mA25mm×30mm99sets

MEWOI7300

MEWOI7300-1_副本.jpg

AC  0.000mA~60.00A1uA25mm×30mm99sets

MEWOI7300E

MEWOI7300-1_副本.jpg

DC  0.0mA~6.00A0.1mA25mm×30mm99sets

MEWOI7500

MEWOI7500_副本.jpg

AC  0.00mA~300.0A0.01mA35mm×40mm99sets

MEWOI7600

MEWOI7600-1_副本.jpg

AC  0mA~600A1mA35mm×40mm99sets

MEWOI7800

MEWOI7800_副本.jpg

AC  0.00mA~1200A0.01mAφ68mm99sets

MEWOI7800E

MEWOI7800E_副本.jpg

AC 0.0A~1500A ,DC 0.0A~2000A0.1Aφ68mm99sets

For Flexible Coil Leakage Current Monitoring Recorder/Logger
SELECTION GUIDE 2

Click "Blue" marked MODEL NO.to view the Spec

Model No.RangeAccuracy:Clamp mouthColi LengthLCD displayData StorageData uploadRS232 interfaceWorking Time
MEWOI9000GMEWOI9000G_80.pngAC 0.00A~20KA(50/60Hz)AC 0.01AΦ300mm1000mm44mm×27mm4200sets100hours
MEWOI9000GBMEWOI9000GB_80.pngAC 0.00A~6000A(50/60Hz)AC 0.01AΦ200mm630mm44mm×27mm4200sets100hours

Specification

Function

Measurement of AC/DC current, leakage current

Power Supply

Zn-Mn dry battery,6F22,9V, continuous use for 100h

Test Mode

Clip-on CT, noncontact measurement

Clamp Size

φ7mm

Measurement Range

0mA~60.0A AC/DC

Resolution

1mA AC/DC

Accuracy

±2%rdg±5dgt (23℃±5℃, below 75%rh)

Display Mode

Four digits LCD display

Dimension

LWH: 168mm×65mm×34mm

LCD Dimension

35mm×21.5mm; display domain: 32mm×15mm

Sampling Rate

2 times/s

Frequency

AC: 45Hz-400Hz

Polarity Indication

DC current auto identified and display“—”

Test Position

Tested wire in the jaw center

Range Shift

Automatically

Line Voltage

AC600V

RS232 Interface

Data stored in the memory of the meter via RS232 upload to PC

Com-Configure

Baud rate:9600, data bit:8, stop bit:1, check bit: NONE

Data Memory

99units, FULL blinks when the memory is full

Reading Hold

DH indicating the reading is hold

Out of Range

OL indicating the current is out of range

Auto Power-off

5 Minutes after power on, it will power off automatically to lower the power consumption

Battery Voltage

Indicating the battery voltage is lower than 7.2V.Then the battery have to be changed

Weight

180g(including the battery)

Working Current

10mA

Humiture

-10℃-50℃,below 80%rh

Limit Temperature Error

-10℃-0℃ and 40℃-50℃, within 2%rdg

Humiture Storage

-10℃-60℃,below 70%rh

Insulating Strength

AC 3700V/rms. (between the alloy of the clamp and the housing)

Applicable safety rules

IEC1010-1, IEC1010-2-032, pollution:2, CAT Ⅲ(600V)

Accessories

Meter:1pc; Toolkit:1pc; RS232 communication line;Disk:1pc; Case:1pc 