power supply | DC 7.4V 5200mAh rechargeable lithium battery, the battery is fully charged about 8.4V |
range | 4 clamp method to measure ground resistance: 200Ω |
Grounding resistance: 0.00Ω~20.00kΩ |
Soil resistivity: 0.00Ωm~9000kΩm |
AC current: 1.00mA~500.0A |
Ground voltage: 0.0V~200.0V |
Measurement methods | Tower grounding resistance: 4 clamp method |
Grounding resistance: rated current pole change method |
Soil resistivity: quadrupole method (Wenner method) |
AC current: clamp CT, RMS acquisition |
Ground voltage: voltage division, RMS acquisition |
Current clamp diameter | Φ68mm |
Test frequency | 128Hz/111Hz/105Hz/94Hz(AFC) |
Short circuit test current | AC 55mA max |
Open circuit test voltage | AC 15V max |
Test voltage waveform | sine wave |
display mode | 7-inch color screen, LCD size: 151mm×83mm |
Meter size | Height, width and thickness: 355mm×272mm×164mm |
Standard test lead | 4 strips: red 20m, black 20m, yellow 10m, green 10m 1 each |
Simple test lead | 2: Red 1.6m, 1 black 1.6m each |
Auxiliary ground rod | 4 pieces: φ10mm×250mm (about 935g) |
measure time | Grounding resistance, soil resistivity: about 30 seconds/time |
Communication Interface | With USB interface, software monitoring, storage data can be uploaded to the computer, save and print |
printer | built-in |
data storage | 100 groups, " 001/100 " storage indication, display " 100/100 " means the storage is full |
overflow display | " OL " symbol indicates when overrange overflow occurs |
Auxiliary ground test | With auxiliary ground resistance value test function, 0.00KΩ~20kΩ (100 R + rC<20kΩ, 100 R + rP <20kΩ) |
Alarm function | When the measured value exceeds the alarm setting value, the alarm symbol of “Sir” will prompt |
Automatic shut-down | 30 minutes after power on, automatic shutdown |
battery voltage | When the battery voltage drops to about DC 7.2V±0.1V, the low battery voltage symbol "" will be displayed to remind the meter that it needs to be charged |
Working current | Standby: about 400mA; measurement: about 550mA |
quality | Meter: about 2810g (including battery); current clamp: about 500g × 4; total mass: about 8800g (including accessories) |
Working temperature and humidity | -10℃~40℃; below 80%rh |
Storage temperature and humidity | -20℃~60℃; below 70%rh |
Overload protection | Measuring ground resistance: AC 280V/3 seconds between each port of C(H)-E and P(S)-ES |
Protection class | IP65 (with lid closed) |
Insulation resistance | Above 20MΩ (500V between circuit and case) |
Suitable for safety regulations | IEC61010-1 (CAT III 300V, CAT IV 150V, pollution degree 2); IEC61010-031; IEC61557-1 (grounding resistance); IEC61557-5 (soil resistivity); JJG 366-2004. |