Contact Us for Quotation | Email:mewoi@mewoi.com | Whatsapp: +8618620373879
|
MEWOI3000B+-0.01-200Ω Clamp earth tester,clamp on ground tester,earth resistance tester
INTRODUCTION
Click to download:MEWOI3000B+Manual
Click to download: MEWOI3000B+ Color Page
Click to download: Field Application Guide
Click to download: Selection Map

MEWOI3000B+ Clamp Earth Resistance Tester is widely applied in ground resistance measurement, loop resistance measurement in fields such as electric power, telecommunications, meteorology, oil field, architecture and industrial electrical equipment, etc. When measuring ground system with loop, there is no need to disconnect the ground wire without auxiliary electrode, which means safer and faster. MEWOI3000B+ Clamp Earth Resistance Tester can measure the ground fault which can not be measured by traditional method, can apply in the occasion where traditional methods are unworkable; MEWOI3000B+ Clamp Earth Resistance Tester measures the integrated value of ground resistance and resistance lead. |
APPLICATION

Why earth resistance can be found by only clamping it?
Rx, is defined as earth resistance under test, and R1, R2...Rn are defined as earth resistance of other measuring objects. |

These earth resistances, R1, R2, Rn can be considered that they are connected in parallel. And they can be regarded as a combined resistance Rs. The Rs can be regarded small enough against Rx since a combined resistance consists of several resistances. Following is an equivalent circuit diagram of this circuit.
|

Voltage V is applied to the object (Resistance Rx) measured from the voltage injection transformer CT1, and the current I corresponding to the earth resistance is flowed. The current I is detected with detection transformer CT2, and object (Resistance Rx) measured can be put out by the calculation. (refer to the right diagram) |

SELECTION GUIDE
Digital Earth Resistance Clamp Meter
Click "blue"marked model No. for detailed Specificaiton
Model | Range
| Resolution
| clamp size | RS232 | Data Storge | Other
|
MEWOI3000B+ 
| 0.01Ω-200Ω | 0.001Ω | 65mm×32mm | optional
| 99sets |
|
MEWOI3100B+ 
| ø32mm |
|
MEWOI3000B 
| 55mm×32mm |
|
|
MEWOI3000 
| 0.01Ω-1000Ω | 0.001Ω | 55mm×32mm |
| 99sets |
|
MEWOI3000+ 
| 0.01Ω-1200Ω | 0.001Ω | 65mm×32mm | optional | 99sets |
|
MEWOI3100+ 
| ø32mm |
|
MEWOI3000D 
| 0.01Ω-1000Ω 0.00-30.00A | 0.001Ω,0.05mA | 55mm×32mm |
| 99sets |
|
MEWOI3000D+ 
| 0.01Ω-1200Ω 0.00-20.00A | 0.001Ω,0.05mA | 65mm×32mm | optional | 99sets |
|
MEWOI3100D+ 
| ø32mm |
|
MEWOI3200 
| 0.01Ω-1500Ω 0.00-40.00A | 0.001Ω,0.05mA | 65mm×32m m | √ | 99sets | Rechargable Batteries |
MEWOI3800CA 
| 0.01Ω-100Ω | 0.01Ω | 60mm*30mm,(Closed) | Appoint with RS485 communication interface, provide standard MODBUS-RTU communication protocol | × |
|
MEWOI3800DA 
| 0.01Ω-100Ω | 0.01Ω | 60mm*30mm (Closed), | × | LCD display,warning function. |
MEWOI3800LC 
| 0.01Ω-200Ω | 0.01Ω | Split Type 56mm×26mm | Wired network: RS232,RS485 standard communication protocol Wireless network: RS232、RS485、GSM communication protocol | × |
|
MEWOI3800LD 
| 0.01Ω-200Ω | 0.01Ω | Split Type 56mm×26mm | × | LCD display,warning function. |
MEWOI3900 
| 0.01Ω~2000Ω | 0.01Ω |
|
|
| 2/3-wires measurement, Online |
MEWOI3900C 
| 0.01Ω~2000Ω | 0.01Ω |
|
|
| 2/3-wires measurement, Online,GPRS |
MEWOI4000 
| 0.01Ω~2000Ω; 0~600V | 0.01Ω,1V |
| √ | 400sets | 2/3-wires measurement of earth resistance/voltage |
MEWOI4000D 
| 0.01Ω~2000Ω; 0~600V | 0.01Ω,1V |
| √ | 400sets | 2/3-wires measurement of earth resistance/voltage |
MEWOI4000C 
| earth resistance:0.01Ω~30.00KΩ; soil resistivity:0.01Ωm~9000KΩm; 0~600V | 0.01Ω,0.01Ωm,1V |
| √ | 300sets | 2/3/4-wires measurement of earth resistance,soil resistivity,and earth voltage |
MEWOI4200D 
| earth resistance:0.01Ω~30.00KΩ; soil resistivity:0.01Ωm~9000KΩm; 0~600V | 0.01Ω,0.01Ωm,1V |
| √ | 300sets | 2/3/4-wires measurement of earth resistance,soil resistivity,and earth voltage |
MEWOI4200 
| earth resistance:0.01Ω~30.00KΩ;AC Leakage current: 0.00mA~600A; soil resistivity:0.01Ωm~9000KΩm;Earth Voltage:0.0~100.0V,dual clamp: 0.01Ω-100Ω | 0.01Ω,0.01Ωm,0.01A,0.1V | ø68mm | √ | 2000sets | 2/3/4-wires,selection & dual clamp method to measure the earth resistance,soil resistivity,earth voltage,AC voltage,AC leakage current,warning function.
|
MEWOI4300D 
| earth resistance:0.01Ω~30.00KΩ;AC Leakage current: 0.00mA~600A; soil resistivity:0.01Ωm~9000KΩm;Earth Voltage:0.0~100.0V,dual clamp: 0.01Ω-100Ω | 0.01Ω,0.01Ωm,0.01A,0.1V | ø68mm | √ | 2000sets | 2/3/4-wires,selection & dual clamp method to measure the earth resistance,soil resistivity,earth voltage,AC voltage,AC leakage current,warning function.
|
MEWOI4250 
| Ground resistance:0.10Ω ~ 200Ω(4 clamp method) Ground resistance ( R ):0.10Ω ~ 20KΩ Soil resistivity ( ρ )0kΩm~9000kΩm AC current (A~)1mA~500.0A Ground voltage (V~)0.0V~200.0V | 0.01Ω,0.01Ωm,0.01mA,0.1V | ø68mm | √ | 100sets | Untie-free tower grounding resistance tester |
Meter: 1 piece, Test Ring: 1 Piece, Meter Suitcase: 1 Piece , batteries: 4 PCS ( LR6)