Model | Range | Resolution
| Clamp Size | Power Supply&output
| Hall effect | Current induction output,Direct Coil tap | Others
|
MEWOI107BE | 0mA~60A (AC/DC) | 1mA | Φ7mm | Power Supply: 9VDC, Output:10mV/A,100mV/A, Accuracy 3% | √ |
| Suitable for small spaces AC / DC leakage current, low current test. |
MEWOI108 | 0.0mA~30A (AC) | 0.1mA, Accuracy 0.5% | Φ8 mm |
|
| √ | Suitable for small spaces AC leakage current, harmonic, phase, Power test |
MEWOI114 | 0.00mA~100A(AC) | 0.01mA, Accuracy 1.0% | Φ14 mm |
|
| √ | Suitable for small spaces AC leakage current, harmonic, phase, Power test |
MEWOI115 | 0.00mA~100A | 0.01mA
| 17mm×18mm |
|
| √ | High accuracy AC leakage current |
MEWOI116 | 0.00mA~20A (AC) | 0.01mA,0.5% | Φ16mm |
|
| √ | High accuracy AC leakage current |
MEWOI130 | 0.00mA~30A (AC), 800:1 | 0.01mA,Accuracy: 0.5% | 25*30mm |
|
| √ | Double shielding, anti-jamming capability,suitable for leakage current,small current test. |
MEWOI130E | 0.00A~100mA (DC), | 1mA | 25*30mm | Power supply: 9VDC, output:25mV/1mA,Accuracy: 3% |
|
| Double shielding, anti-jamming capability,suitable for small DC current test. |
MEWOI130E2 | 0.0mA ~100mA (DC), | 0.1mA | 25*30mm | Power supply: 9VDC, output:0~2.5mV/1mA,Accuracy: 3%,Turns ratio:1:800 |
|
| Double shielding, anti-jamming capability,suitable for DC leakage current test. |
MEWOI130BE | 0mA~60A (AC/DC) | 1mA | 25*30mm | Power supply: 9VDC, output:10mV/A,100mV/A,Accuracy: 2% | √ |
| suitable for AC/DC current test |
MEWOI135BE | 0.0A~1000A (AC/DC) | 0.1A | 30*35mm | Power supply: 9VDC, output:1mV/1A,Accuracy: 2% | √ |
| suitable for AC/DC current test |
MEWOI140 | 0.00mA ~40A (AC) Turn Ratio 800:1 | 0.01mA,Accuracy: 0.5% | 35*40mm |
|
| √ | Single shielding, suitable for leakage current, small current test |
MEWOI140B | 0.0A~600A (AC)
Turn Ratio 1:4000
| 0.1A, Accuracy: 1% | 35*40mm |
|
| √ | suitable for big current test |
MEWOI140C | 0.0mA ~100A (AC) Turn Ratio 1:2000 | 0.1mA, Accuracy: 1% | 35*40mm |
|
| √ | suitable for current, harmonic, phase, Power test |
MEWOI140E | DC 0mA~1000mA | 1mA, Accuracy: 3% | 35*40mm | Power supply: 9VDC, output:1mV/1mA,Accuracy: 3% |
|
|
|
MEWOI150 | 0mA ~ 600A AC | 1mA,0.5% | Φ50mm |
|
|
|
|
MEWOI168 | 0.00mA ~60A (AC) | 0.01mA, Accuracy: 0.5% 800:1 | Φ68mm |
|
| √ | Double shielding, anti-jamming capability,suitable for leakage current, current test |
MEWOI168B | 0.0A~800A (AC) | 0.01A, Accuracy: 0.5% 2000:1 / 0~3V(7.5Ω) | Φ68mm |
|
| √ | suitable for current, harmonic, phase, Power test |
MEWOI168C | 0.00A~1000A (AC) | 1mA, Accuracy: 2% | Φ68mm |
|
| √ | suitable for current, harmonic, phase, Power test |
MEWOI168BE | 0.0A~1500A (DC), 0.0A~1500A(AC) | 0.1A | Φ68mm | Power supply: 9VDC, output:1mV/1A, Accuracy: 3% | √ |
| suitable for AC/DC big current test
|
MEWOI170 | 0mA ~ 1000A | 1mA | Φ70mm | output signal: mA/A;mV/A;1A;5A |
|
|
|
MEWOI180 | AC 0.00mA~60A
| 0.01mA 0.5% 800:1 | 80X80mm |
|
|
|
|
MEWOI248 | AC 0.0mA~100A | 0.1mA 0.5% 800:1 | 108X148mm |
|
|
|
|